![Siemens SITRANS F Function Manual Download Page 40](http://html.mh-extra.com/html/siemens/sitrans-f/sitrans-f_function-manual_374463040.webp)
Setup
3.1 Sensor settings
FST030
38
Function Manual, 04/2017, A5E35693328-AA
3.1.7
User calibration
3.1.7.1
Slope
Description
A single point flow correction applied to volume flow equally at any flow rate.
Q = Q * Slope (e.g. Slope of 0.99 = -1% correction)
Setting 0.5 to 2.0
Default 1.0
Related
Path
Setup → Sensor settings → User calibration → Slope
3.1.7.2
Path 1 offset
Description
User calibrated zero offset for path 1.
Delta time offset correction value, which can be determined at zero flow.
Setting -1250ns to 1250ns
Default 0.0
Related
Path
Setup → Sensor settings → User calibration → Path 1 offset
3.1.7.3
Path 2 offset
Description
User calibrated zero offset for path 2.
Delta time offset correction value, which can be determined at zero flow.
Setting -1250ns to 1250ns
Default 0.0
Related
Path
Setup → Sensor settings → User calibration → Path 2 offset
Summary of Contents for SITRANS F
Page 1: ...Function Manual Answers for industry 04 2017 Edition Ultrasonic Flowmeters FST030 SITRANS F ...
Page 2: ......
Page 18: ...Table of contents FST030 16 Function Manual 04 2017 A5E35693328 AA ...
Page 24: ...Quick Start 2 5 Copy configuration FST030 22 Function Manual 04 2017 A5E35693328 AA ...
Page 332: ...Communication 5 3 Modbus Channel 1 FST030 330 Function Manual 04 2017 A5E35693328 AA ...
Page 336: ...Security 6 8 Logout FST030 334 Function Manual 04 2017 A5E35693328 AA ...
Page 338: ...Language 7 1 Language FST030 336 Function Manual 04 2017 A5E35693328 AA ...
Page 340: ...Support A 1 Technical support FST030 338 Function Manual 04 2017 A5E35693328 AA ...
Page 346: ...Glossary FST030 344 Function Manual 04 2017 A5E35693328 AA ...
Page 348: ...Index FST030 346 Function Manual 04 2017 A5E35693328 AA ...
Page 349: ......