SFIDK.PS.029.Y1.02
24
SITRANS F US SONOFLO
Description of
hot-tap alignment
tool for pipe sizes
DN 300 - DN 1200
For use on pipe sizes in the range DN 300 to DN 1200
(1)
Cradle for mounting on the pipe after the transducer locations have been marked
(2)
Awe used to position the cradle
(3)
Centre holder for mounting on the cradle to keep the alignment barrels in the right position
(4)
Adaptor to keep the transducer holder in the right position before the welding. Two pcs are
supplied
(5)
Holders to keep the vertical rods and the rods holding the transducer in the right position
during installation
(6)
The cradle can be tack welded onto the pipe. On non weldable pipes, use the enclosed
webbing spanners
(7)
Alignment rods - 8 pcs in set
Ø = 25 mm, L = 500 mm
Siemens Flow Instruments code no. FDK:085B5393
(1)
(6)
(7)
(2)
(3)
(4)
(5)