SFIDK.PS.029.Y1.02
17
SITRANS F US SONOFLO
Pull back the snap coupling and remove
the mandrel.
Tighten the transducer by means of the
pipe wrench.
Remove the brass adaptor from the trans-
ducer by means of a fork spanner.
Mount spring clips and silicone plug.
The hot-tap installation of this transducer
is now finished. Continue with the re-
maining transducers following the same
procedure.