SITRANS F C MC2
Operating Instructions, 10/2009, A5E02154544-02
37
Technical data
9
Mm
20
25
40
50
65
80
100
150
Versions
Inch
¾
1
1½
2
2½
3
4
6
Number of
measuring pipes
2
Inside pipe diameter 2 x mm
8.0
10.0
16.0
22.0
29.0
34.0
43.1
76.1
Pipe wall thickness Mm
1
1
1
1.5
1.5
2.0
2.6
3.2
Mass flow
measuring range at
pressure drop of 2
bar at 1 g/cm
3
Kg/h
4600
7360
21850
42600
87000
113400 192000 510000
Density
Kg/dm
3
0.5-3.5
Fraction e.g. Brix
Brix
0-100
Standard
-50 to +180〬C
Temperature
Ex
-20 to +180〬C
Liquid pressure
measuring pipe
Stainless steel (DIN
2413, 20〬C)
PN
100
100
100
100
100
100
40
40
Standard
SS 1.4571 or Hastelloy C4
Materials, Wetted
parts
Hygienic
SS 1.4435 (316L)
Enclosure
IP67
Enclosure material /
connection box
1.4301 / aluminium
Process
connections
See Dimensions (Page 43)
Electrical
connections
Screw terminals, M20
Cable length
m
Max. 300
Cable connection
5 x 2 x o.35 mm
2
twisted and screened in pairs, ext. Ø 12mm
Ex-version
ATEX 1443X
II 2G EEx em [ib] IIC T6 (≤ DN 40 [1½"])
II 1/2 EEx em [ib] II C T6 (> DN 50 [2"])
Weight approx
kg
13
14
18
34
47
58
91
260
Output
Table 9- 1
Display / frequency and pulse output MC2 sensors
5%
50%
100%
DN 20
150 kg/h
3000 kg/h
4600 kg/h