SITRANS F C MASSFLO
26
SFIDK.PS.028.R1.02
ENGLISH
Meter size and process connection
Pipe thread
DI 1.5
DI 3
DI 6
DI 15
DI 25
DI 40
G
1
/
4
“ ISO 228-1 ..........................................................................................
1901
1911
1921
1
/
4
“ NPT, ANSI/ASME B 1.20.1 .....................................................................
1902
1912
1922
G
1
/
2
“ ISO 228-1 ................................................................................................................................
1933
1
/
2
“ NPT, ANSI/ASME B 1.20.1 ...........................................................................................................
1934
G 1“ ISO 228-1 ...............................................................................................................................................
1945
1“ NPT, ANSI/ASME B 1.20.1 .........................................................................................................................
1946
G 2“ ISO 228-1 ..........................................................................................................................................................
1957
2“ NPT, ANSI/ASME B 1.20.1 ....................................................................................................................................
1958
Wetted materials
1.4435 (Stainless steel 316L) .....................................................................................................................................................
0
2.4602 (Hastelloy C-22) (not available in DI 40) ..........................................................................................................................
1
Heated sensor (Except for DI 1.5)
No heating connection .........................................................................................................................................................................
0
Flange heating connection: DIN 2635, PN 40 ......................................................................................................................................
1
Flange heating connection: ANSI B 16.5 Class 150 ............................................................................................................................
2
Version DI 1.5
Sensor ATEX 1G EEx ia IIC T4-T6 (max. 125°C) ...................................................................................................................................
2
Sensor ATEX 1G EEx ia IIC T3-T6 (max. 180°C) ...................................................................................................................................
3
Versions DI 3, DI 6, DI 15, DI 25, and DI 40
Sensor ATEX 1G EEx ia IIC T3-T6 ..........................................................................................................................................................
1
Sensor ATEX 1G EEx ia IIC T3-T6 inclusive compact ATEX 2G EEx de [ia/ib] IIC T6 converter .......................................................
D
Sensor inclusive compact IP 67, 24 V a.c./d.c. converter ....................................................................................................................
E
Sensor inclusive compact IP 67, 230 V a.c./d.c. converter .................................................................................................................
F
Configuration
Standard ............................................................................................................................................................................................................
0
Density ..............................................................................................................................................................................................................
1
Brix/Plato ...........................................................................................................................................................................................................
2
Fraction flow (specified by customer), contact Siemens Flow Instruments .....................................................................................................
Z
Flow calibration
Standard calibration included in sensor (3 flow x 2 points) ........................................................................................................................................
A
Standard calibration, matched pair (3 flow x 2 points; FDK:085F7351) ......................................................................................................................
B
Customer specified, matched pair (5 flow x 2 points; FDK:085F7372) .......................................................................................................................
C
Accredited calibration (EN 45001), certificate DANAK, matched pair (5 flow x 2 points; FDK:085F7382) .................................................................
D
Customer specified calibration, non matched pair (5 flow x 2 points; FDK:085F7353) ...............................................................................................
E
Certificate EN 45014 (for wetted parts)
None ...................................................................................................................................................................................................................................
0
Pressure testing PED 97/23/EC .........................................................................................................................................................................................
1
None ...........................................................................................................................................................................................................................................
0
Material certificate EN10204-3.1B ..............................................................................................................................................................................................
1
None ...................................................................................................................................................................................................................................................
0
Welding certificate NDT, X-ray, EN 25817/B
(Not possible to get on DI 1.5 and DI 3 sensors) .........................................................................................................
1
7.2
Build-up ordering - High pressure versions
A
Pressure rating [bar]
Size
Material
20
°°°°°
C
180
°°°°°
C
Test pressure at 20
°°°°°
C
DI 1.5
316L
230
200
350
DI 1.5
C-22
365
330
550
DI 3
316L
230
230
350
DI 3
C-22
350
310
525
DI 6
316L
265
250
400
DI 6
C-22
410
350
620
DI 15
316L
130
115
200
DI 15
C-22
200
160
300
DI 25
316L
110
105
170
DI 25
C-22
185
145
280
DI 40
316L
105
95
160
DI 40
C-22
170
130
260
Max. pressure
MASS 2100 -
7. Ordering