SITRANS F C MASSFLO
25
SFIDK.PS.028.R1.02
ENGLISH
7. Ordering
MASS 2100 -
Meter size and process connection
Pipe thread (only available with type of contact faces ‘A’)
DI 1.5
DI 3
DI 6
DI 15
DI 25
DI 40
G
1
/
4
“ ISO 228-1, PN 100 .............................................................................
1401
1411
1421
1
/
4
“ NPT, ANSI/ASME B 1.20.1, PN 100 .......................................................
1402
1412
1422
G
1
/
2
“ ISO 228-1, PN 100 ....................................................................................................
1433
1
/
2
“ NPT, ANSI/ASME B 1.20.1, PN 100 ..............................................................................
1434
G 1“ ISO 228-1, PN 100 ......................................................................................................
1445
1“ NPT, ANSI/ASME B 1.20.1, PN 100 ................................................................................
1446
G 2“ ISO 228-1, PN 100 ......................................................................................................
1457
2“ NPT, ANSI/ASME B 1.20.1, PN 100 ................................................................................
1458
Flange
DN 10, DIN 2635, PN 40 ......................................................................................................
2221
DN 15, DIN 2635, PN 40 ......................................................................................................
2222
2232
DN 25, DIN 2635, PN 40 ......................................................................................................
2233
2243
DN 40, DIN 2635, PN 40 ......................................................................................................
2245
2255
DN 50, DIN 2635, PN 40 ......................................................................................................
2256
DN 10, DIN 2637, PN 100 ....................................................................................................
2421
DN 15, DIN 2637, PN 100 ....................................................................................................
2422
2432
DN 25, DIN 2637, PN 100 ....................................................................................................
2433
2443
DN 40, DIN 2637, PN 100 ....................................................................................................
2445
2455
DN 50, DIN 2637, PN 100 ....................................................................................................
2456
1
/
2
“,
ANSI B 16.5, Class 150, (ISO 7005-1, PN 20) .........................................................
3121
3131
3
/
4
“,
ANSI B 16.5, Class 150, (ISO 7005-1, PN 20) .........................................................
3122
3132
1“,
ANSI B 16.5, Class 150, (ISO 7005-1, PN 20) .........................................................
3143
1
1
/
2
“, ANSI B 16.5, Class 150, (ISO 7005-1, PN 20) .........................................................
3145
3155
2“,
ANSI B 16.5, Class 150, (ISO 7005-1, PN 20) .........................................................
3156
1
/
2
“,
ANSI B 16.5, Class 600, (ISO 7005-1, PN 100) ........................................................
3421
3431
3
/
4
“,
ANSI B 16.5, Class 600, (ISO 7005-1, PN 100) ........................................................
3422
3432
1“,
ANSI B 16.5, Class 600, (ISO 7005-1, PN 100) ........................................................
3443
1
1
/
2
“, ANSI B 16.5, Class 600, (ISO 7005-1, PN 100) ........................................................
3445
3455
2“,
ANSI B 16.5, Class 600, (ISO 7005-1, PN 100) ........................................................
3456
Dairy (only available with type of contact faces ‘A’)
DN 10, DIN 11851 (screwed connection) PN 40 ..................................................................
4221
DN 15, DIN 11851 (screwed connection) PN 40 ..................................................................
4222
4232
DN 25, DIN 11851 (screwed connection) PN 40 ..................................................................
4233
DN 32, DIN 11851 (screwed connection) PN 40 ..................................................................
4244
DN 40, DIN 11851 (screwed connection) PN 25 ..................................................................
4245
DN 50, DIN 11851 (screwed connection) PN 25 ..................................................................
4256
DN 65, DIN 11851 (screwed connection) PN 25 ..................................................................
4257
25 mm, Clamp, SMS 3016, ISO 2852, BS 4825 part 3, PN 16 ............................................
5123
5133
38 mm, Clamp, SMS 3016, ISO 2852, BS 4825 part 3, PN 16 ............................................
5146
51 mm, Clamp, SMS 3016, ISO 2852, BS 4825 part 3, PN 16 ............................................
5158
25 mm, ISO 2853, SS 3351, BS 4825 part 4 (screwed connection), PN 16 .......................
6123
6133
38 mm, ISO 2853, SS 3351, BS 4825 part 4 (screwed connection), PN 16 ................................................
6146
51 mm, ISO 2853, SS 3351, BS 4825 part 4 (screwed connection), PN 16 .............................................................
6158
Type of contact faces
For pipe thread / Dairy connection. State ‘A’ only ................................................................................................................
A
End Flange Facings DIN 2526, form C (PN 40), form E (PN 100)/ANSI B 16.5 (ISO 7005-1) type 11 ................................
B
End Flange Facings DIN 2512 Nut form N ...........................................................................................................................
C
End Flange Facings ANSI B 16.5 (ISO 7005-1) small groove .............................................................................................
D
Wetted materials
1.4435 (Stainless steel 316L) .....................................................................................................................................................
0
2.4602 (Hastelloy C-22)
(Only available for connections specified as standard versions, exclusive dariy connections) ...........
1
Heated sensor (Except for DI 1.5)
No heating connection .........................................................................................................................................................................
0
Flange heating connection: DIN 2635, PN 40 ......................................................................................................................................
1
Flange heating connection: ANSI B 16.5 Class 150 ............................................................................................................................
2
Version DI 1.5
Sensor ATEX 1G EEx ia IIC T4-T6 (max. 125°C) ...................................................................................................................................
2
Sensor ATEX 1G EEx ia IIC T3-T6 (max. 180°C) ...................................................................................................................................
3
Versions DI 3, DI 6, DI 15, DI 25, and DI 40
Sensor ATEX 1G EEx ia IIC T3-T6 ..........................................................................................................................................................
1
Sensor ATEX 1G EEx ia IIC T3-T6 inclusive compact ATEX 2G EEx de [ia/ib] IIC T6 converter .......................................................
D
Sensor inclusive compact IP 67, 24 V a.c./d.c. converter ....................................................................................................................
E
Sensor inclusive compact IP 67, 230 V a.c./d.c. converter .................................................................................................................
F
Configuration
Standard ............................................................................................................................................................................................................
0
Density ..............................................................................................................................................................................................................
1
Brix/Plato ...........................................................................................................................................................................................................
2
Fraction flow (specified by customer), contact Siemens Flow Instruments .....................................................................................................
Z
Flow calibration
Standard calibration included in sensor (3 flow x 2 points) ........................................................................................................................................
A
Standard calibration, matched pair (3 flow x 2 points; FDK:085F7351) ......................................................................................................................
B
Customer specified, matched pair (5 flow x 2 points; FDK:085F7372) .......................................................................................................................
C
Accredited calibration (EN 45001), certificate DANAK, matched pair (5 flow x 2 points; FDK:085F7382) .................................................................
D
Customer specified calibration, non matched pair (5 flow x 2 points; FDK:085F7353) ...............................................................................................
E
Certificate EN 45014 (for wetted parts)
(Certificate not available for dairy connections, material 1.4404 or 1.4435)
None ...................................................................................................................................................................................................................................
0
Pressure testing PED 97/23/EC .........................................................................................................................................................................................
1
None ...........................................................................................................................................................................................................................................
0
Material certificate EN10204-3.1B ..............................................................................................................................................................................................
1
None ...................................................................................................................................................................................................................................................
0
Welding certificate NDT, X-ray, EN 25817/B
(Not possible to get on DI 1.5 and DI 3 sensors) .........................................................................................................
1
7.1
Build-up ordering
Standard versions
(Hastelloy not available in DI 40)