3SK1111-.AB..
3SK1111-.AW..
Control supply voltage
•
for DC rated value
V
24
—
– minimum
V
—
110
– maximum
V
—
240
•
at 50 Hz at AC rated value
V
24
—
– minimum
V
—
110
– maximum
V
—
240
•
at 60 Hz at AC rated value
V
24
—
– minimum
V
—
110
– maximum
V
—
240
operating range factor control supply voltage
rated value of the magnet coil
0.85
•
at 50 Hz for AC
1.1
0.85
•
at 60 Hz for AC
1.1
0.85
•
for DC
1.2
1.1
Active power loss typical
W
2
2.5
Contact reliability of the auxiliary contacts
—
Product function parameterizable
Sensor floating / sensor
non-floating, monitored start
/ autostart
Sensor floating / monitored
start / autostart
Suitability for use device connector 3ZY12
No
Suitability for interaction pressing control
No
Suitability for use
•
safety cut-out switch
Yes
•
monitoring of floating sensors
Yes
•
monitoring of non-floating sensors
Yes
No
•
magnetically operated switches monitoring
Yes
No
•
safety-related circuits
Yes
Summary of Contents for SIRIUS 3SK1