SIPROTEC Modbus - Bus mapping 7VE61, 7VE63
C53000-L1840-C017-03

,QSXWUHJLVWHUV;UHIHUHQFHV

The Input register block allows the Modbus master to read the values of the the analog 
inputs of the SIPROTEC device (recorded measured values).

1RWH

Depending on the device composition not all of the indicated analog inputs (and 
corresponding Modbus registers) may be available in the SIPROTEC device.

The pre-allocated measured values are transferred as secondary values per 
default.

Changes of the scaling of the measured values are possible in adaption to the con-
crete installation environment.
You find information about this in the manual “SIPROTEC Communication module, 
Modbus - Communication profile” (ref. to page i)

5HJLVWHU

'HVLJQDWLRQRIWKH

6,3527(&REMHFWV

&RPPHQWV

6FDOLQJ

FRUUHVSRQGVWR

,QWHUQDO

REMHFWQR

30001

V1 =

Measured value V1

3276,7 V

25044

30002

V2 =

Measured value V2

3276,7 V

25045

30003

f1 =

Measured value f1

327,67 Hz

25046

30004

f2 =

Measured value f2

327,67 Hz

25047

30005

dU =

Measured value dU

3276,7 V

25048

30006

df =

Measured value df

327,67 Hz

25049

30007

d

α

 =

Measured value d

α

3276,7 °

25050

30008

<user-defined>

not pre-allocated

-

-

30009

<user-defined>

not pre-allocated

-

-

30010

<user-defined>

not pre-allocated

-

-

30011

<user-defined>

not pre-allocated

-

-

30012

<user-defined>

not pre-allocated

-

-

30013

<user-defined>

not pre-allocated

-

-

Summary of Contents for SIPROTEC 7VE61

Page 1: ...Revision 1 0 Edition July 2003 C53000 L1840 C017 03 SIPROTEC Multifunction Paralleling Devices 7VE61 7VE63 Communication module Modbus Bus mapping 3UHIDFH 7DEOH RI FRQWHQWV 0RGEXV UHJLVWHU PDS 1 QGH ...

Page 2: ...hnical improvements without notice RS ULJKW Copyright Siemens AG 2003 All rights reserved Dissemination or reproduction of this document or evaluation and commu nication of its contents is not authorized except where expressly permitted Violations are liable for damages All rights reserved particularly for the purposes of patent application or trademark registration 5HJLVWHUHG WUDGHPDUNV SIPROTEC ...

Page 3: ...es you find in the SIPROTEC4 System Manual order no E50417 H1176 C151 0RGEXV FRPPXQLFDWLRQ SURILOH GRFXPHQWDWLRQ The following additional manual informs you about the data types bus specific param eters and hardware inteface of the Modbus slave modul of the SIPROTEC devices 0RGEXV VSHFLILFDWLRQ The Modbus specification with a detailed explanation of the Modbus protocol is contained in MODICON Modb...

Page 4: ...mber of standard mappings GGLWLRQDO 6XSSRUW For questions regarding SIPROTEC4 devices please contact your Siemens repre sentative 7UDLQLQJ FRXUVHV Individual course offerings may be found in our Training Catalog and questions can be directed to our Training Centre Please contact your Siemens representative 7DUJHW DXGLHQFH Protection engineers commissioning engineers personnel concerned with adjust...

Page 5: ... also applies to selection items for selection menus QQXQFLDWLRQV or identifiers for information produced by the device or required by other devices or from the switchgear is shown in mono script same point size and placed into quotation marks For diagrams in which the identifier type results from the representation itself text con ventions may differ from the above mentioned DUQLQJ During operati...

Page 6: ...3UHIDFH iv SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 7: ...ping 7VE61 7VE63 C53000 L1840 C017 03 5HYLVLRQ LQGH Listing of the changes between the editions of this manual 0RGLILHG FKDSWHUV SDJHV GLWLRQ 5HDVRQV RI PRGLILFDWLRQ 1 0 First edition Doc No C53000 L1840 C017 03 July 30th 2003 ...

Page 8: ...5HYLVLRQ LQGH vi SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 9: ... 1 3 Input Status registers 1X references 1 7 1 3 1 Registers 10001 to 10016 Single point indications taggings 1 7 1 3 2 Registers 10017 to 10029 Error messages synchronization 1 8 1 3 3 Registers 10030 to 10095 Synchronization 1 8 1 4 Input registers 3X references 1 11 1 5 Holding registers 4X references 1 12 1 5 1 Registers 40001 to 40036 System information 1 12 1 5 2 Registers 40065 to 40069 Ti...

Page 10: ...7DEOH RI FRQWHQWV viii SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 11: ...hapter describes the register map organization of the Modbus slave of the SIPROTEC devices 7VE61 7VE63 1 1 Explanations 1 2 1 2 Coil Status registers 0X references 1 3 1 3 Input Status registers 1X references 1 7 1 4 Input registers 3X references 1 11 1 5 Holding registers 4X references 1 12 ...

Page 12: ...ts in the register mapping 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV 6FDOLQJ FRUUHVSRQGV WR QWHUQDO REMHFW QR 30001 V1 Measured value V1 3276 7 V 25044 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 10017 25 MonTimeExc 1 25 Monitoring time exceeded 222 2025 01 1RWH The description of the standard mappings contains the pre allocation of the map ping files DW GHOLYHU RU ...

Page 13: ... the SIPROTEC devices Depending on the device composition there may be less than indicated output relays and corresponding Modbus registers available in the SIPROTEC device 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 00001 user defined not pre allocated 00002 user defined not pre allocated 00003 user defined not pre allocated 00004 user defined not pre allocated 00005 user ...

Page 14: ...ot pre allocated 00030 user defined not pre allocated 00031 user defined not pre allocated 00032 user defined not pre allocated 00033 user defined not pre allocated 00034 user defined not pre allocated 00035 user defined not pre allocated 00036 user defined not pre allocated 00037 user defined not pre allocated 00038 user defined not pre allocated 00039 user defined not pre allocated 00040 user de...

Page 15: ...ivation of setting group C Indication Setting Group C 0 Setting group C is not active 1 Setting group C is active 00048 Command Setting Group D 0 not permitted 1 Activation of setting group D Indication Setting Group D 0 Setting group D is not active 1 Setting group D is active KDQJLQJ WKH VHWWLQJ JURXS In order to change the setting group the value 1 ON must be transmitted to the corresponding re...

Page 16: ...s also readable using function Read Exception Status function code 7 Installation specific SIPROTEC objects can be routed on these register positions using parameterization system DIGSI 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 00049 user defined ON not pro allocated 00050 user defined OFF 00051 user defined ON not pro allocated 00052 user defined OFF 1 A write access is ...

Page 17: ...n of the devices Depending on the device composition and the existing protection packages not all of the indicated binary inputs or protection annunciations and corresponding Mod bus registers may be available in the SIPROTEC device 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 10001 user defined not pre allocated 10002 user defined not pre allocated 10003 user defined not pr...

Page 18: ...up 8 Parameter not plausible 170 2097 08 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 10030 25 1 activ 1 25 Function group 1 is active 170 2311 01 10031 25 2 activ 1 25 Function group 2 is active 170 2311 02 10032 25 3 activ 1 25 Function group 3 is active 170 2311 03 10033 25 4 activ 1 25 Function group 4 is active 170 2311 04 10034 25 5 activ 1 25 Function group 5 is activ...

Page 19: ...038 01 10066 25 V2 1 25 Voltage V2 Umax permissible 222 2039 01 10067 25 V2 1 25 Voltage V2 Umin permissible 222 2040 01 10068 25 V2 V1 1 25 Vdiff too large V2 V1 222 2090 01 10069 25 V2 V1 1 25 Vdiff too large V2 V1 222 2091 01 10070 25 f2 f1 1 25 fdiff too large f2 f1 222 2092 01 10071 25 f2 f1 1 25 fdiff too large f2 f1 222 2093 01 10072 25 α2 α1 1 25 alphadiff too large α2 α1 222 2094 01 10073...

Page 20: ...7 10089 25 CloseRel 2 1 25 Release of Close Command 2 7 170 2301 07 10090 25 CloseRel 1 1 25 Release of Close Command 1 8 170 2300 08 10091 25 CloseRel 2 1 25 Release of Close Command 2 8 170 2301 08 10092 25 V2 down 1 25 decrease voltage V2 222 2324 01 10093 25 V2 up 1 25 increase voltage V2 222 2325 01 10094 25 f2 down 1 25 decrease frequency f2 222 2326 01 10095 25 f2 up 1 25 increase frequency...

Page 21: ... the con crete installation environment You find information about this in the manual SIPROTEC Communication module Modbus Communication profile ref to page i 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV 6FDOLQJ FRUUHVSRQGV WR QWHUQDO REMHFW QR 30001 V1 Measured value V1 3276 7 V 25044 30002 V2 Measured value V2 3276 7 V 25045 30003 f1 Measured value f1 327 67 Hz 25046 30004 f2 Measured value...

Page 22: ...tion module string max 16 characters AME GEN for AME module AMO GEN for AMO module 40009 40010 Communication module software revision Example Register 40009 0001H register 40010 0205H Revision 1 2 5 40011 40026 MLFB order number of the SIPROTEC device string max 32 characters Example 7VE61105EB910DB1 0D 40027 40034 Date and time of mapping data generation string max 16 characters Example 170203095...

Page 23: ...dbus Communication profile for additional notes regarding methods of time synchronization and Time Date data type 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV 40065 Milliseconds Time Date transfer registers 40066 Hours Minutes 40067 Month Day 40068 Time Date status byte Year 40069 Set Time and Date available only if time synchronization is configured with use of the Set Time and Date register...

Page 24: ...e vice completed after initial start or restart 51 40129 21 ProtActive 1 At Least one protection function is active 52 40129 22 user defined not pre allocated 40129 23 Error Sum Alarm 1 Error with a summary alarm ON 140 40129 24 Alarm Sum Event 1 Alarm summary event ON 160 40129 25 Relay PICKUP 1 Relay PICKUP group signal 501 40129 26 Relay TRIP 1 Relay GENERAL TRIP command 511 40129 27 user defin...

Page 25: ... on these register positions as Destination system interface using the 6 RQILJXUDWLRQ PDWUL 1 A write access is rejected with exception code 03 ILLEGAL_DATA_VALUE 5HJLVWHU HVLJQDWLRQ RI WKH 6 3527 REMHFWV RPPHQWV QWHUQDO REMHFW QR 40301 40302 user defined not pre allocated 40303 40304 user defined not pre allocated 40305 40306 user defined not pre allocated 40307 40308 user defined not pre allocat...

Page 26: ...ted 40352 40355 Time Date Time and Date of the user defined Min Max value 40356 user defined not pre allocated 40357 40360 Time Date Time and Date of the user defined Min Max value 40361 user defined not pre allocated 40362 40365 Time Date Time and Date of the user defined Min Max value 40366 user defined not pre allocated 40367 40370 Time Date Time and Date of the user defined Min Max value 40371...

Page 27: ...o chap Customization of the allocations in the manual SIPROTEC Communication module Modbus Communication profile 1 A write access is rejected with exception code 03 ILLEGAL_DATA_VALUE 5HJLVWHU HVLJQDWLRQ RPPHQWV 40601 No of Event recorder entries Number of Event recorder entries which still were not read 40602 SOE_Control Handshake register read write access 40603 Message block 1 Register type Bit...

Page 28: ...0RGEXV UHJLVWHU PDS 1 18 SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 29: ...Function Chart 5 Cyclical Redundancy Check Double Command 6 Parameterization system parameterization software for SIPROTEC devices 3 Double point indication QSXW GDWD QSXW GLUHFWLRQ Data from the Modbus slave to the Modbus master 5 Longitudinal Redundancy Check 6 Least Significant Byte 0DSSLQJ Allocation of the SIPROTEC data objects to the positions in the Modbus register map 06 Most Significant B...

Page 30: ... ORVVDU 5 2 SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 31: ...egisters 1 12 Input registers 1 11 Input Status registers 1 7 0 Measured values Min Max values 1 16 Message blocks 1 17 4 Qualified personnel definition P iii 6 Seqence of Events Event recorder Single commands 1 3 Single point indications 1 7 Statistic values 1 15 Synchronization 1 8 Error messages 1 8 7 Target audience P ii Time synchronization 1 13 Typographic conventions P iii 9 Validity of the...

Page 32: ... QGH 3 2 SIPROTEC Modbus Bus mapping 7VE61 7VE63 C53000 L1840 C017 03 ...

Page 33: ...Berlin Germany Dear reader printing errors can never be entirely eliminated therefore should you come across any when reading this manual kindly enter them in this form together with any comments or suggestions for improvement that you may have URP Name Company Dept Address Phone no Fax no RUUHFWLRQV 6XJJHVWLRQV ...

Page 34: ...r communication of the contents thereof are forbidden with out express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design Order no C53000 L1840 C017 03 Siemens Aktiengesellschaft ...

Reviews: