SIPLUS CMS X-Tools - Release Notes 

SIPLUS CMS

English 
Release 2012-09 

 9 / 12

 

 

2.26 

Too small Ring Buffers may confuse Storage Profiles 

In case the ring buffer of an offline data is much too small (e.g. it is overwritten multiple times per second), a 
Storage Profile which is using this online data as input may not detect this error and can produce unwanted 
results without a notification to the user. 

2.27 

Automatic Assigning of Sequence IDs can cause Damage 

In case of Analyzing Models/User Functions which use recursion, the automatic assigning of sequence IDs can 
result in an order of sequence which does not allow the desired calculation to run properly. 

2.28 

Possible wrong first Timestamps from ION SIMATIC TDC T001 Devices 

The first timestamps which are delivered by an ION SIMATIC TDC T001 directly after the start of its Device 
Profile can be wrong. They can cause log entries about timestamp errors after the start. 

2.29 

No cancelling of the Post Trigger Time through Storage Profiles for offline 
Data 

Storage Profiles which use offline data as input do not cancel the post trigger time even in case a start event 
occurs during the post trigger time. 

2.30 

Memory Management 

Although the memory management has been significantly improved in V 03.05, it is not able to cover all possible 
effects of low memory. The current memory management does not consider the fragmentation of the address 
room of the process, it does not use a totally deterministic approach for the order of Configuration Files and it 
does not react in case the maximal free block of the process drops too low. The possible effects are that the 
status of currently suspended and running Configuration Files is dependent to values which are not clearly visi-
ble to the user and that the status can be different for the same Configuration Files at different moments in time. 

2.31 

Data Snapshots may freeze the X-Tools Client 

In case a to-be-created data snapshot has to process a big amount of data, the X-Tools Client could freeze 
during this time. 

2.32 

Delay during the Creation of automatic Reports for offline Data 

Monitoring Views which create reports on base of offline data may wait up to one second after each created 
report. This delay can cause a long processing time in case of long offline data and/or a lot of to-be-created 
reports. 

2.33 

/openMVF may discard changed Monitoring Views 

In case /openMVF is used in order to open an already opened Monitoring View and in case this already opened 
Monitoring View contains unsaved changes, /openMVF discards all of these changes and opens the Monitoring 
View according to the current settings within the file at the disk. 

2.34 

Possibly not established Connection to Socket Devices 

In case an Interface Profile for socket devices was paused it may not be able to establish the connection to its 
configured devices after it is continued. 

2.35 

Pausing of Monitoring Views in low Memory Situations 

Pausing of Monitoring Views may fail in case there is not enough memory available for the copying of the cur-
rently displayed online data. 

Summary of Contents for SIPLUS CMS

Page 1: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 1 12 Preface 1 Release Notes 2 SIPLUS CMS List of Abbreviations 3 SIPLUS CMS X Tools Release Notes Contact Information 4 English Release 2012 09 ...

Page 2: ...ission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components from other manufacturers approved or recommended by Siemens Thi...

Page 3: ... 7 Unsupported Update of the ANF FFT and of windowing ANFs within Analyzing Scripts 2 17 7 Unsupported Update of the ANF OutTCP within Analyzing Scripts 2 18 8 Impaired loading of very big Offline Data Files 2 19 8 Device Name of ION SIMATIC TDC T001 Devices 2 20 8 Legacy IEEE1394 Driver of Windows 7 2 21 8 OPC UA Server Endpoint URL 2 22 8 Multiple OPC UA Server Endpoints 2 23 8 OPC UA Output Dat...

Page 4: ...IPLUS CMS English Release 2012 09 4 12 9 2 35 Pausing of Monitoring Views in low Memory Situations 2 36 10 Band Recognition through MonSpmEnv 2 37 10 Band Recognition through MonXYEnv 3 11 List of Abbreviations 4 12 Contact Information ...

Page 5: ... about the functionality which is provided by the Device Management System SIPLUS CMS X Tools User Manual 05 Monitoring System o provides detailed information about the functionality which is provided by the Monitoring System SIPLUS CMS X Tools User Manual 06 Analyzing System o provides detailed information about the functionality which is provided by the Analyzing System SIPLUS CMS X Tools User M...

Page 6: ...shall be connected via IEEE1394 is restricted to 30 participants 2 3 Usage of IEEE1394 Cables Do not to use cables for the electrical connection of IEEE1394 with a length of 0 5 m or with a length of longer than 4 5 m 2 4 Usage of multiple CTN WatchGuard T001 It is not possible to use multiple CTN WatchGuard T001 at once at the same computer 2 5 Data Supervision Time for CTN WatchGuard T001 Device...

Page 7: ...ine also setting of the data supervision time to e g 10 seconds can reduce this effect 2 14 Massive Amounts of Log Entries may be caused by the Sequence Control The sequence control can be used in order to automatically start and stop any other Configuration File Each of such operation causes one or more entries to the System Log and each entry consumes a few bytes of mem ory thus the overall memo...

Page 8: ...r Endpoint URL The X Tools Server uses the combination of Domain Name IP Address and the port number as endpoint URL to connect to an OPC UA server It does not read the provided endpoint URL from the OPC UA server In case the OPC UA server needs the exact endpoint URL definition the X Tools Server may not be able to connect to this OPC UA server Examples IP Address 192 168 10 20 Port 4841 o the re...

Page 9: ...se a totally deterministic approach for the order of Configuration Files and it does not react in case the maximal free block of the process drops too low The possible effects are that the status of currently suspended and running Configuration Files is dependent to values which are not clearly visi ble to the user and that the status can be different for the same Configuration Files at different ...

Page 10: ...first call for the further monitoring and would use amplitudes of 0 for the monitoring in case no valid spectrum is provided at the first call 2 37 Band Recognition through MonXYEnv The upper and lower bands which are provided via the inputs of the Analyzing Function MonXYEnv must pro vide a valid buffer at the moment of the first call at the first cycle of the parent Analyzing Model Analyzing Scr...

Page 11: ...tor IFN Interface Node ION I O Node Input Output Node IPE Interface Profile Editor LPE Loading Profile Editor MDS Master Data System MDX Master Data System Explorer MMS Main Management System MMX Main Management System Explorer MPE Main Profile Editor MTC Monitoring Chart MTS Monitoring System MTX Monitoring System Explorer MVE Monitoring View Editor ODL Offline Data Loader RPN Repeater Node UAE U...

Page 12: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 12 12 4 Contact Information Address Siemens AG I IA CE SE Wuerzburger Strasse 121 90766 Fuerth Germany Internet http www siemens com siplus cms ...

Reviews: