SIPLUS CMS X-Tools - Release Notes 

SIPLUS CMS

English 
Release 2012-09 

 8 / 12

 

 

2.18 

Impaired loading of very big Offline Data Files 

X-Tools

 may be unable to load offline data files with a size of 100 MBytes or more. In case the offline data files 

are too big, also an interval-based loading mode can fail because of insufficient RAM. The only possibility to 
load parts of such big offline data is to use a “Time Input Mode” of “Minimum Time and Time Interval”, “Minimum 
Time and Maximum Time” or “Time Interval and Maximum Time” and to specify a smaller period of time of the 
offline data file for the loading. 

2.19 

Device Name of ION SIMATIC TDC T001 Devices 

In case an ION SIMATIC TDC T001 is renamed via the 

DMS Explorer

 of the 

X-Tools Client

 and in case the 

new name is longer than 200 characters, the used TDC rack can fall into a system error. A restart of the TDC 
rack is necessary in this case. 

2.20 

Legacy IEEE1394 Driver of Windows 7 

Microsoft Windows 7 is delivered with two versions of the basic IEEE1394 bus driver: The so-called “new” driver 
with advanced support for IEEE1394b devices and the so-called “legacy” driver. In case the new driver is in-
stalled and the IEEE1394 devices are not detected or operating properly, the legacy driver must be installed. 
The legacy driver also must be installed in case the used IEEE1394 host adapter uses an IEEE1394-1995 PHY. 

Refer to the user manual for detailed information about how to switch between the new and the legacy driver. 

2.21 

OPC UA Server Endpoint URL 

The 

X-Tools Server

 uses the combination of Domain Name/IP Address and the port number as endpoint URL 

to connect to an OPC UA server. It does not read the provided endpoint URL from the OPC UA server. In case 
the OPC UA server needs the exact endpoint URL definition, the 

X-Tools Server

 may not be able to connect to 

this OPC UA server. 

Examples: 

  IP Address = 192.168.10.20, Port = 4841 

o

  the resulting Endpoint URL would be “opc.tcp://192.168.10.20:4841” 

  Domain Name = Localhost, Port = 52520 

o

  the resulting Endpoint URL would be “opc.tcp://Localhost:52520” 

2.22 

Multiple OPC UA Server Endpoints 

The 

X-Tools Server

 does not support multiple endpoint URLs. In case the OPC UA server provides more than 

one endpoint URL, the 

X-Tools Server

 tries to connect in the same way as described above. 

2.23 

OPC UA Output Data Table 

Cyclically writing of values to OPC UA variables (Output Data Table in OPC UA Device Profile) will not work, if 
there is no variable defined for reading (Input Data Table in OPC UA Device Profile). You have to add as mini-
mum one variable to the Input Data Table. This input variable can be disabled, so it will not appear as Online 
Data in the MDS Explorer. 

2.24 

Possible wrong automatic Update of Analyzing Models/User Functions 

In case the new version of an Analyzing Function provides a smaller amount of configurable input or output 
arguments, the automatic update through the AME Standard T001 or UFE Standard T001 may fail. 

2.25 

Missing Offset Compensation for ION AnalogInput T001 Devices 

The hardware offset of ION AnalogInput T001 devices is not compensated during the measurement. Therefore, 
the measured values from the 8 channels can be different by several digits. 

Summary of Contents for SIPLUS CMS

Page 1: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 1 12 Preface 1 Release Notes 2 SIPLUS CMS List of Abbreviations 3 SIPLUS CMS X Tools Release Notes Contact Information 4 English Release 2012 09 ...

Page 2: ...ission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components from other manufacturers approved or recommended by Siemens Thi...

Page 3: ... 7 Unsupported Update of the ANF FFT and of windowing ANFs within Analyzing Scripts 2 17 7 Unsupported Update of the ANF OutTCP within Analyzing Scripts 2 18 8 Impaired loading of very big Offline Data Files 2 19 8 Device Name of ION SIMATIC TDC T001 Devices 2 20 8 Legacy IEEE1394 Driver of Windows 7 2 21 8 OPC UA Server Endpoint URL 2 22 8 Multiple OPC UA Server Endpoints 2 23 8 OPC UA Output Dat...

Page 4: ...IPLUS CMS English Release 2012 09 4 12 9 2 35 Pausing of Monitoring Views in low Memory Situations 2 36 10 Band Recognition through MonSpmEnv 2 37 10 Band Recognition through MonXYEnv 3 11 List of Abbreviations 4 12 Contact Information ...

Page 5: ... about the functionality which is provided by the Device Management System SIPLUS CMS X Tools User Manual 05 Monitoring System o provides detailed information about the functionality which is provided by the Monitoring System SIPLUS CMS X Tools User Manual 06 Analyzing System o provides detailed information about the functionality which is provided by the Analyzing System SIPLUS CMS X Tools User M...

Page 6: ...shall be connected via IEEE1394 is restricted to 30 participants 2 3 Usage of IEEE1394 Cables Do not to use cables for the electrical connection of IEEE1394 with a length of 0 5 m or with a length of longer than 4 5 m 2 4 Usage of multiple CTN WatchGuard T001 It is not possible to use multiple CTN WatchGuard T001 at once at the same computer 2 5 Data Supervision Time for CTN WatchGuard T001 Device...

Page 7: ...ine also setting of the data supervision time to e g 10 seconds can reduce this effect 2 14 Massive Amounts of Log Entries may be caused by the Sequence Control The sequence control can be used in order to automatically start and stop any other Configuration File Each of such operation causes one or more entries to the System Log and each entry consumes a few bytes of mem ory thus the overall memo...

Page 8: ...r Endpoint URL The X Tools Server uses the combination of Domain Name IP Address and the port number as endpoint URL to connect to an OPC UA server It does not read the provided endpoint URL from the OPC UA server In case the OPC UA server needs the exact endpoint URL definition the X Tools Server may not be able to connect to this OPC UA server Examples IP Address 192 168 10 20 Port 4841 o the re...

Page 9: ...se a totally deterministic approach for the order of Configuration Files and it does not react in case the maximal free block of the process drops too low The possible effects are that the status of currently suspended and running Configuration Files is dependent to values which are not clearly visi ble to the user and that the status can be different for the same Configuration Files at different ...

Page 10: ...first call for the further monitoring and would use amplitudes of 0 for the monitoring in case no valid spectrum is provided at the first call 2 37 Band Recognition through MonXYEnv The upper and lower bands which are provided via the inputs of the Analyzing Function MonXYEnv must pro vide a valid buffer at the moment of the first call at the first cycle of the parent Analyzing Model Analyzing Scr...

Page 11: ...tor IFN Interface Node ION I O Node Input Output Node IPE Interface Profile Editor LPE Loading Profile Editor MDS Master Data System MDX Master Data System Explorer MMS Main Management System MMX Main Management System Explorer MPE Main Profile Editor MTC Monitoring Chart MTS Monitoring System MTX Monitoring System Explorer MVE Monitoring View Editor ODL Offline Data Loader RPN Repeater Node UAE U...

Page 12: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 12 12 4 Contact Information Address Siemens AG I IA CE SE Wuerzburger Strasse 121 90766 Fuerth Germany Internet http www siemens com siplus cms ...

Reviews: