8.9
Use of Ethernet interfaces
Application
The following connections can be established via the Ethernet interfaces:
● X127: Commissioning and for remote diagnostics.
● X130: Connecting the MCU with the company network.
● X1 P1 and X2 P1: Connecting the MCU with the company network under Windows as well
as using the MCU under Windows.
You can find further details in the following manuals:
● SINUMERIK ONE Commission Manual, Basic Software and Operating Software
● SIMATIC TS Adapter IE Manual
Properties
The interfaces are full duplex 10/100/1000 Mbit Ethernet ports. The ports are connected as an
Ethernet end device.
Pin assignment
For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange LED.
This allows the following status information about the respective Ethernet port to be displayed:
Table 8-5
Assignment of Ethernet interfaces X1 P1, X2 P1, X3 P1, X127 P1 and X130 P1 in the 1 GBit/
s mode
Connector
Pin
Name
Type
Remark
/('
/('
1
DA+
B
Bidirectional pair A+
2
DA-
Bidirectional pair A-
3
DB+
Bidirectional pair B+
4
DC+
Bidirectional pair C+
5
DC-
Bidirectional pair C-
6
DB-
Bidirectional pair B-
7
DD+
Bidirectional pair D+
8
DD-
Bidirectional pair D-
Shield
-
-
On connector housing
-
LED green
(Link)
-
Off: 10 Mbit/s
Lights up green: 100 Mbit/s
Lights up orange: 1000 Mbit/s
-
LED orange
(Activity)
-
Flashes: Data exchange
Off: No data exchange
Signal type: B = Bidirectional
Connecting
8.9 Use of Ethernet interfaces
MCU 1720
Equipment Manual, 09/2019, A5E47437728B AB
71
Summary of Contents for SINUMERIK MCU1720
Page 6: ...Table of contents MCU 1720 6 Equipment Manual 09 2019 A5E47437728B AB ...
Page 10: ...Preface MCU 1720 10 Equipment Manual 09 2019 A5E47437728B AB ...
Page 44: ...Dimension drawings 6 3 Portrait mounting MCU 1720 44 Equipment Manual 09 2019 A5E47437728B AB ...
Page 56: ...Installation 7 5 Mounting strain reliefs MCU 1720 56 Equipment Manual 09 2019 A5E47437728B AB ...
Page 96: ...Safety symbols MCU 1720 96 Equipment Manual 09 2019 A5E47437728B AB ...