Figure 6-4
Grounding lug
6.5.3
Preparations for connecting the power cables
● Disconnect the cabinets from the power supply.
● Ensure that all the necessary safety measures have been taken at the installation location.
● Allow unimpeded access to the cable clamping bar in the cabinets.
6.5.4
Connecting power cables
①
Contact surface
Figure 6-5
Example: Connecting the power cables
1. Clean the contact surfaces immediately before screwing the connections. Use spirit and a
lintless cloth for cleaning.
2. Apply a thin film of grease. Electrolube 2G is a suitable lubricator.
3. Screw the cable lug with a M12 screw and, if necessary, with a washer to the contact
surface. Tighten the nuts with a torque of 50 Nm.
Electrical connection
6.5 Connection
SINAMICS SM150 6SL3845-2NN41-8AD0
92
Operating Instructions Rev.201908010908 EXAMPLE
Summary of Contents for Sinamics SM150 6SL3845-2NN41-8AD0
Page 2: ...01 08 2019 09 08 V32 00 ...
Page 98: ...Start up SINAMICS SM150 6SL3845 2NN41 8AD0 98 Operating Instructions Rev 201908010908 EXAMPLE ...
Page 187: ......
Page 190: ......
Page 192: ......