3RV
3RV
3RV
3RV
3RV
3RV
3RV
=
=
①
Expanding rivets
②
Expanding rivets
③
Expanding rivets
④
Overall configuration, curtain
Pos. 10 Makrolon plate, center front
Pos. 20 Makrolon strip, left
Pos. 60 Makrolon strip, right
Figure 5-5
Dust protection cover, closed-loop control cabinet
1. Using flat-nose pliers, pull off all expanding rivets
①
and remove the Makrolon plate
"Pos. 10".
2. Pull off the two expanding rivets
②
of the curtain
④
using flat-nose pliers, and remove the
curtain.
3. Using flat-nose pliers, pull off all expanding rivets
③
of the two Makrolon strips "Pos. 20,
Pos. 60" and remove the side strips.
5.10.3
Removing the dust protection cover of the inverter cabinet
Note
All Makrolon parts that need to be removed are marked with a red sticker and the item number.
Installation
5.10 Removing the dust protection cover
SINAMICS SM150 6SL3815-7NP41-0AA1
Operating Instructions Rev.201910281301 EXAMPLE
95