WARNING
Electric shock when opening plug connections in operation
When opening plug connections in operation, arcs can result in severe injury or death.
● Only open plug connections when the equipment is in a no-voltage state, unless it has
been explicitly stated that they can be opened in operation.
For applications in line with UL, only the following components are permitted to supply
SINAMICS S120M components:
Table 3-7
Active Line Modules booksize
Heat dissipation
16 kW
36 kW
55 kW
80 kW
Internal air cooling
6SL3130-
7TE21-6A..
7TE23-6A..
7TE25-5A..
7TE28-0A..
External air cooling
6SL3131-
Cold plate cooling
6SL3136-
Operation of the components of the SINAMICS S120M system on Active Line Modules Booksize with 120 kW power is not
certified.
Table 3-8
Basic Line Modules booksize
Heat dissipation
20 kW
40 kW
Internal air cooling
6SL3130-
1TE22-0A..
1TE24-0A..
Cold plate cooling
6SL3136-
Operation of the components of the SINAMICS S120M system on Basic Line Modules Booksize with 100 kW power is not
certified.
Table 3-9
Smart Line Modules booksize
Heat dissipation
5 kW
10 kW
16 kW
36 kW
55 kW
Internal air cooling
6SL3130-
6AE15-0A..
6AE21-0A..
6TE21-6A..
6TE23-6A..
6TE25-5A..
External air cooling
6SL3131-
Cold plate cooling
6SL3136-
-
Table 3-10
Smart Line Modules Booksize Compact
Heat dissipation
16 kW
Internal air cooling
6SL3430-
6TE21-6A..
Operation is only permitted on line supplies with a maximum rated voltage of 480 V AC and a
maximum short-circuit current of 65 kA (symmetrical) if Line Modules permitted in this manual
System overview
3.4 SINAMICS S120 components
Manual, 06/2019, 6SL3097-5AW00-0BP1
43
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......