6.4
Options for Motor Menu (1) - second half
Table 6-6
Encoder Menu (1280) Parameters: Closed Loop Vector Control only
Parameter
ID
Unit
Default
Min
Max
Description
Encoder 1
PPR
1290
720
1
10000
Enter the rated number of pulses per revolution delivered
by the encoder. See nameplate value.
Encoder fil‐
ter gain
1300
0.75
0.1
0.999
Set the gain of the filter for encoder feedback. This param‐
eter can have a value between 0.0 i.e., no filtering, and
0.999 i.e., maximum filtering.
Encoder loss
threshold
1310
%
5.0
1.0
75.0
Set the level for the error between encoder output and cal‐
culated motor speed to determine encoder loss.
Encoder loss
response
1320
Stop (on
fault)
Set the drive response to a loss of encoder event:
• Stop (on fault)
• Open Loop (control). If Open Loop is selected, set motor
slip to zero.
Table 6-7
Current Profile Menu (1092) Parameters
Parameter
ID
Unit
Default
Min
Max
Description
Motor current
limit 1
1193
%
100
10
300
Current limit 1 set point for speed/current profile.
Speed at cur‐
rent lim 1
1194
%
100
-200
200
Motor speed point 1 on the speed/current profile curve.
Motor current
limit 2
1195
%
100
10
300
Current limit 2 set point for speed/current profile.
Speed at cur‐
rent lim 2
1196
%
100
-200
200
Motor speed point 2 on the speed/current profile curve.
Motor current
limit 3
1197
%
100
10
300
Current limit 3 set point for speed/current profile.
Speed at cur‐
rent lim 3
1198
%
100
-200
200
Motor speed point 3 on the speed/current profile curve.
Motor current
limit 4
1202
%
100
10
300
Current limit 4 set point for speed/current profile.
Speed at cur‐
rent lim 4
1203
%
100
-200
200
Motor speed point 4 on the speed/current profile curve.
Motor current
limit 5
1204
%
100
10
300
Current limit 5 set point for speed/current profile.
Speed at cur‐
rent lim 5
1205
%
100
-200
200
Motor speed point 5 on the speed/current profile curve.
Motor current
limit 6
1206
%
100
10
300
Current limit 6 set point for speed/current profile.
Speed at cur‐
rent lim 6
1207
%
100
-200
200
Motor speed point 6 on the speed/current profile curve.
Motor current
limit 7
1208
%
100
10
300
Current limit 7 set point for speed/current profile.
Speed at cur‐
rent lim 7
1209
%
100
-200
200
Motor speed point 7 on the speed/current profile curve.
Parameter Assignment/Addressing
6.4 Options for Motor Menu (1) - second half
Control Manual
Operating Manual, A5E50491925A
97
Summary of Contents for SINAMICS PERFECT HARMONY GH180
Page 2: ......
Page 22: ...Table of contents NXGPro Control Manual 20 Operating Manual A5E50491925A ...
Page 24: ...Security NXGPro Control Manual 22 Operating Manual A5E50491925A ...
Page 504: ...NEMA Table NXGPro Control Manual 502 Operating Manual A5E50491925A ...
Page 517: ...Index D NXGPro Control Manual Operating Manual A5E50491925A 515 ...
Page 518: ...Index NXGPro Control Manual 516 Operating Manual A5E50491925A ...
Page 530: ...Glossary NXGPro Control Manual 528 Operating Manual A5E50491925A ...
Page 537: ......