Electrical connection
6.7 External control voltage
Installation and Operating Instructions SINAMICS G180
Operating Instructions, 02/2019, 4BS0751-007
105
Preparing compact devices with size up to 225 mm
This instruction is applicable for compact units up to a size of 225 mm with the identifier
2T..-07400-015 or 2T..-07500-037.
Procedure
1.
Turn the four fixing screws of the gray cover through 90° and lift up the cover.
2.
Unscrew the blue cover at the screw above -X25 and lift up the cover.
3.
Turn the four fixing screws of the swivel section by 90°, swivel the swivel section to the
right and clip the swivel section to the side panel according to the picture below.
4.
Replug the connector.
5.
Reassemble in the inverse order.
Compact frame size 165 mm long
Compact frame size 225 mm long