Activating the service mode
1. On the IPC desktop, open link "AppLocker".
2. Select script "010_disable_applicationcontrol".
3. In the shortcut menu, execute command "Run as administrator".
The service mode is activated. The whitelist is deactivated.
4. Install the software and/or the updates.
Deactivating the service mode
1. Select script "020_whitelist".
2. In the shortcut menu, execute command "Run as administrator".
Executing the script can take several minutes. You can ignore the alarms that are output.
The service mode is activated. Whitelisting is deactivated.
3. Select script "030_enable_ applicationcontrol_wo_DLL".
4. In the shortcut menu, execute command "Run as administrator".
The IPC restarts.
The service mode is deactivated. The whitelist is reactivated.
Result
The software and/or the updates are installed and entered into the whitelist.
See also
9.3
Updating Windows
Regularly and promptly loading software updates is an important element of a comprehensive
security concept. Software updates play an important role in ensuring stable system operation
when it comes to closing security gaps that have been identified.
Automatic Windows updates are activated in the factory. The "Windows Update Server" is the
default source for Windows updates.
Before carrying out an update, create recovery points for both "C:" and "D:" partitions. Carry out
pending Windows updates. You can connect the IPC to the company's own Windows update
server.
Additional information
Additional information relating to recovery points is provided in Chapter "Setting recovery
points (Page 29)" and in the Microsoft Windows Help.
Maintenance
9.3 Updating Windows
SINAMICS CONNECT 500
42