5.3.7.2
Global measuring on C240/C240 PN (B1-B4)
The inputs B1-B4 are available for global measuring on the C240. These can be used for one-
off or cyclic measuring.
Note
For more information about the measuring input on C240/C240 PN, refer to the
C2xx
Operating Instructions.
To configure a measuring input on a C240/C240 PN (B1-B4) (global measuring)
1. Insert a new measuring input (see Inserting measuring inputs section) or use an existing
one.
2. Parameterize the measuring input (see the Parameterization of the measuring input
technology object section)
3. Double-click Configuration below the measuring input in the project navigator. The
Configuration window appears in the working area.
4. Activate the option Standard (global measuring input). If symbolic assignment is not active
or if the CPU version < V4.2, a physical output is assigned by entering the HW address
and bit number in the Output field.
5. Enter the HW address and the bit number. The hardware address and the bit number can
be ascertained in HW Config (e.g. 64.2 for the measuring input Pin 3 of connector X1).
6. Click OK to close the window and select Project > Save.
See also
5.3.7.3
Global measurement on D4xx, D410-2, D4x5-2 (X122/X132), CX32, CX32-2, CU310,
CU310-2, CU320 and CU320-2
On D4xx, D410-2, D4x5-2, CX32, CX32-2, CU310, CU310-2 and CU320 you have digital
inputs to connect to a global measuring input. These can be used for one-off or cyclic
measuring.
If symbolic assignment is not active or if the CPU version < V4.2, the following applies:
The measurement results are transmitted by standard telegrams 391/392 and 393/396 (only
D410-2/CU310-2/D4x5-2/CX32-2/CU320-2) and not via the axis telegram.
Measuring Input TO - Part III
5.3 Configuring the Measuring Input technology object
Output Cams and Measuring Inputs
Function Manual, 04/2014
167