Description of the motor
2.5 Selection and ordering data
1FW3 complete torque motors
34
Configuration Manual, 08/2020, A5E46027705B AA
Motor type
Rated current /
stall current
I
N
[A] / I
0
[A]
Order designation (Article No.)
Motor Module SINAMICS S120
Rated current
Motor Module
I
N
[A]
Rated pulse frequency
Motor
f
pulseN
[kHz]
Line supply voltage of 400 V 3 AC, Active Line Module (V
mot
= 425 V)
*)
1FW3287-2
☐
E
230 / 234
6SL3320-1TE32-6AA
☐
260
2
1FW3287-2
☐
G
352 / 365
6SL3320-1TE33-8AA
☐
380
2
1FW328
☐
High Speed
1FW3281-3
☐
J
188 / 200
6SL3120-1TE32-0AA
☐
200
4
1FW3281-3
☐
M
256 / 291
6SL3320-1TE33-1AA
☐
310
2
1FW3281-3
☐
P
315 / 403
6SL3320-1TE33-8AA
☐
380
2
1FW3283-3
☐
J
275 / 292
6SL3320-1TE33-1AA
☐
310
2
1FW3283-3
☐
M
357 / 402
6SL3320-1TE33-8AA
☐
380
2
1FW3283-3
☐
P
424 / 538
6SL3320-1TE35-0AA
☐
490
2
1FW3285-3
☐
J
376 / 400
6SL3320-1TE33-8AA
☐
380
2
1FW3285-3
☐
M
469 / 532
6SL3320-1TE35-0AA
☐
490
2
1FW3285-3
☐
P **
)
638 / 806
6SL3320-1TE38-4AA
☐
731
2
1FW3287-3
☐
J **
)
504 / 534
6SL3320-1TE37-5AA
☐
618
2
1FW3287-3
☐
M **
)
696 / 787
6SL3320-1TE38-4AA
☐
731
2
1FW3287-3
☐
P **
)
830 / 830
6SL3320-1TE41-0AA
☐
906
2
*
)
Other supply voltages can also be configured in SIZER.
**
)
The rated output current of the motor module includes a derating factor due to the pulse frequency.
Note
Sound pressure level when reducing the pulse frequency
When the pulse frequency is reduced, a significantly higher sound pressure level can occur.
Summary of Contents for SIMOTICS T-1FW3
Page 1: ...1FW3 complete torque motors ...
Page 2: ......
Page 8: ...Introduction 1FW3 complete torque motors 6 Configuration Manual 08 2020 A5E46027705B AA ...
Page 12: ...Table of contents 1FW3 complete torque motors 10 Configuration Manual 08 2020 A5E46027705B AA ...
Page 353: ......
Page 354: ......