Maintenance
8.2 Corrective maintenance
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
137
Running in the bearings
Once you have replaced the bearings, allow the rolling-contact bearings to run in to distribute
the grease evenly. When doing so, the motors should be initially run continuously from 0 to
approx. 75 % of the maximum speed n
max
over a period of 15 minutes.
8.2.2
Removing/installing the speed encoder
Note
Removing/installing the encoder
•
Unscrew the terminal box cover and disconnect the power cables.
•
Unscrew the external fan unit (if installed) and the encoder cover.