Attaching the cover
If you are installing covers that are sealed with liquid gasket, proceed as follows to maintain the
IP degree of protection of the machine before closing it again:
1. Use only approved liquid sealants.
2. Clean the sealing surfaces according to the technical data sheet of the liquid sealant. The
sealing surfaces must be clean and dry before reassembly.
3. Apply the liquid gasket as a continuous bead with a diameter of approx. 3 mm.
4. Assemble the components after the solvent has had a chance to vaporize, while still
assembling within the specified assembly time.
5. Retighten the fixing screws of the cover after the liquid sealant has set.
If you have any questions, contact the Service Center.