6
6-6
PG 720 Programming Device
C79000-G7076-C720-02
In the “Power Management Feature Control” menu, you can set the power
management functions. This allows you to regulate the power consumption of
your PG 720 to suit the mode you are working in. This function is particularly
important in making best use of the battery.
Phoenix SETUP Utility (Version X.XX)
(c) Phoenix Technologies Ltd. 1985, 1994 All Rights Reserved
Standby Timeout:
Suspend Timeout:
LCD\CRT Mode:
Maximum CPU Speed:
** Power Management Feature Control **
Page 3 of 3
ESC
Menu
F1
Help
Field
+ / Ć
Value
6 minutes
10 minutes
Standby Off
Full Speed
Fixed Disk Timeout:
Disabled
Resume Modem Ring:
Enabled
Power Management: Battery only
Page
PgUp/Dn
F2
PM Min.
F3
PM Max.
Figure 6-3
“Power Management” Menu Page
With the power management menu, the SETUP program provides you with
several defaults that make it easier to set the power management values. The
following table shows the possible settings.
Table 6-4
Selectable Parameters in Power Management
Parameter
Setting
Effect
Disabled
No power management
high-performance mode
Enabled
F 2
PM Min.
Minimum power management - maximum power
consumption; high-performance mode
F 3
PM Max.
Maximum power management - low power consumption;
long life mode (slower)
Battery only
F 2
PM Min.
Only in battery operation; minimum power management -
maximum power consumption - high-performance mode
F 3
PM Max.
Only in battery operation; maximum power management - low
power consumption; long life mode
Define Power
Management
Defaults
Configuring the Programming Device
Summary of Contents for SIMATIC PG 720
Page 32: ...3 3 18 PG 720 Programming Device C79000 G7076 C720 02 Getting to Know the PG 720 ...
Page 56: ...4 4 24 PG 720 Programming Device C79000 G7076 C720 02 Installing the PG 720 ...
Page 76: ...6 6 10 PG 720 Programming Device C79000 G7076 C720 02 Configuring the Programming Device ...
Page 80: ...7 7 4 PG 720 Programming Device C79000 G7076 C720 02 Error Diagnostics ...