8-18
PG 720 P Programming Device
C79000-G7076-C721-02
If you want to connect your PG 720 to the S5/RS-232 port of a PG 6xx
programming device, you require an adapter. In this case, the PG 720 must
be the active programming device. Please read the information about
activating and deactivating the TTY/COM1 port in Chapter 4.
PG 7xx
25-pin male Cannon
25-pin male Cannon connector
COM/TTY port
activated
Adapter
6ES5 731-6AG00
(Release 2)
Connecting cable
6ES5 733-2xxx0
PG 6xx
with S5 PLC/V.24 port
deactivated
330 ohms
330 ohms
19
18
21
22
10
6
8
19
9
8
21
10
12
10
24
25
12
23
20
6
2
3
4
17
24
25
2
3
4
17
1
3
20
Casing
Casing
Shield/casing
GND
K3
K2
K1
+V
–V
+V
–V
Figure 8-14
Connecting to the S5/RS-232 and COM1/TTY Ports of a PG 6xx
Programming Device
Connection to S5
PLC/RS-232 and
COM1/TTY of a
PG 6xx
Hardware Information