Certification
6.2 EMC and Environmental Type Tests
•
EN 50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
•
NEMA TS-2
Traffic Controller Assemblies with NTCIP Requirements
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RSL910 has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 6 kV
3
IEC
61000-4-2
ESD
Enclosure Air
± 8 kV
3
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
10 and 20 V/m
3
Signal Ports
± 2 kV
4
DC Power
Ports
± 2 kV
3
AC Power
Ports
± 2 kV
3
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 1 kV
2
Signal Ports
± 2 kV
2
DC Power
Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
1
IEC
61000-4-5
Surge
AC Power
Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
2
Signal Ports
10 V
3
DC Power
Ports
10 V
3
AC Power
Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC
61000-4-8
Magnetic Field
Enclosure
Ports
30 A/m
IEC
61000-4-11
Voltage Dips and Interrupts
AC Power
Ports
30% for 25 Periods
60% for 10 Periods
100% for 1 Period
40
RUGGEDCOM RSL910
Installation Manual, 04/2022, C79000-G8976-1305-13