Edition
01/2021
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM M969
https://www.siemens.com
Page 1: ...Edition 01 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M969 https www siemens com ...
Page 2: ...ernet Switches RUGGEDCOM M969 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Accessories 6 Certification 7 01 2021 C79000 G8976 1039 03 ...
Page 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...
Page 4: ...ng the Device 9 2 2 Mounting the Device 10 2 3 Connecting the Failsafe Alarm Relay 11 2 4 Connecting Power 12 2 4 1 Power Supply Connector Pin Out 12 2 4 2 Power Supply Wiring 13 2 4 3 Disabling Line to Ground Transient Protection 16 3 Device Management 17 3 1 Connecting to the Device 17 3 2 Configuring the Device 18 4 Communication Ports 19 4 1 Copper Ethernet Ports 20 4 2 Fiber Optic Ethernet Po...
Page 5: ...30 6 3 Failsafe 1 unit 31 6 4 Ethernet 8 unit 32 6 5 LC Fiber Optic 2 unit 35 7 Certification 39 7 1 Approvals 39 7 1 1 CSA 39 7 1 2 European Commission EC 39 7 1 3 FCC 40 7 1 4 FDA CDRH 40 7 1 5 ISED 40 7 1 6 ISO 41 7 1 7 ACMA 41 7 1 8 RoHS 41 7 1 9 Other Approvals 42 7 2 MIL STD Test Specifications 42 7 3 EMC and Environmental Type Tests 43 iv RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8...
Page 6: ...Trademarks RUGGEDCOM and ROS are trademarks of Siemens AG Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years from the date of purchase conditional upon the return to factory for maintenance during the warranty term This product contains no ...
Page 7: ...ed with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical...
Page 8: ...y Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 vii ...
Page 9: ...Preface Contacting Siemens viii RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 10: ...working functions advanced cyber security features and a full array of intelligent functionality for high network availability and manageability Coupled with the ruggedized hardware design the RUGGEDCOM M969 is ideal for creating mission critical real time control applications in any harsh environment 1 1 Feature Highlights Ethernet Ports Two Fiber Optical Fast Ethernet Ports 100Base X or Gigabit ...
Page 11: ...r ultimate redundancy Available with M23 style connectors CSA UL 62368 1 safety approved to 85 C 185 F Simple Plug and Play Operation Automatic learning of up to 8192 MAC addresses Auto negotiation on all 10 100Base TX ports 100FX on optic fiber ports Auto MDI MDIX crossover on all 10 100Base TX ports LED indicators for link and activity 1 2 Description The RUGGEDCOM M969 features various ports co...
Page 12: ... 11 1 Copper Ethernet Ports 2 Port Status LED 3 POWER 1 LED 4 POWER 2 LED 5 ALARM LED 6 RS 232 Console Port 7 Failsafe Output Relay 8 M12 Power Supply Port 9 Fiber Optic Ethernet Ports RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 3 ...
Page 13: ...Ground Connection 11 Chassis Ground Connection Figure 1 1 RUGGEDCOM M969 M12 Connectors Shown 10 9 11 1 2 4 3 5 7 6 8 1 Copper Ethernet Ports 2 Port Status LED 3 POWER 1 LED 4 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 14: ...safe Alarm Relay Specifications Page 23 Power Supply Terminal The power supply port For more information refer to Connecting Power Page 12 Power Supply Specifications Page 23 RS 232 Console Port For interfacing directly with the device and accessing initial management functions For information about connecting to the device via the console port refer to Connecting to the Device Page 17 Copper Fibe...
Page 15: ... Ethernet ports Siemens does not recommend the use of copper cabling of any length for critical real time substation automation applications All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850 3 and IEEE 1613 Class 1 standards This means that during a transient electrical event commu...
Page 16: ... equipment on the basis of the degree of protection provided by the enclosure These ratings are determined by specific tests The RUGGEDCOM M969 Industrial Ethernet Switch is manufactured and tested to IP67 standards With an IP67 rating a product will be dust tight and remain completely sealed when immersed in water to a depth of 1 meter for 1 hour IEC 60529 These caps completely seal off unused po...
Page 17: ...Introduction 1 6 Ingress Protection 8 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 18: ...viceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restricted access location where access can only be gained by author...
Page 19: ...ards from the enclosure As such it is recommended that 2 5 cm 1 in of space be maintained on all open sides of the device to allow for some convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device wi...
Page 20: ... the flanges to the panel 2 3 Connecting the Failsafe Alarm Relay The Failsafe output relay is provided to signal critical error conditions that may occur on the RUGGEDCOM M969 series switches The contacts are energized upon power up of the unit and remain energized until a critical error occurs One common application for this output is to signal an alarm if a power failure or removal of control p...
Page 21: ... 2 4 1 Power Supply Connector Pin Out The following is the pin out for the M23 A coded power supply connector M23 Power Supply Connector 5 4 3 2 1 Figure 2 3 M23 Power Supply Connector Terminal Description Usage 1 PS1 Live PS1 Live is connected to the positive terminal if the power source is DC or to the Live terminal if the power source is AC 2 PS1 Neutral PS1 Neutral is connected to the negative...
Page 22: ...s DC or to the Live terminal if the power source is AC 2 4 2 Power Supply Wiring The following illustrates how to connect the RUGGEDCOM M969 to a single or dual power supplies Note For 100 240 VAC rated equipment a 250 VAC appropriately rated circuit breaker must be installed For 88 300VDC rated equipment a 300VDC appropriately rated circuit breaker must be installed A circuit breaker is not requi...
Page 23: ...wer Connector Single Low DC Power Supply Wiring 4 5 3 2 1 1 2 3 5 1 M23 Power Connector 2 Ground Bus 3 300 VDC Breaker 4 DC Power Source Figure 2 5 DC Power Supply Wiring Example M23 Connector Dual AC DC Power Supply Wiring M23 Connector Only 1 2 6 4 5 8 4 5 3 2 1 7 4 5 3 3 1 M23 Power Connector 2 Ground Bus 3 Line 14 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 24: ...C Power Supply Wiring Example 1 2 4 5 3 2 1 6 4 5 7 3 3 5 1 M23 Power Connector 2 Ground Bus 3 Line 4 250 VAC Breaker 5 110 230 VAC Power Source PS2 6 Neutral 7 Safety 8 300 VDC Breaker 9 DC Power Source PS1 Figure 2 7 AC and DC Power Supply Wiring Example 3 2 1 4 5 1 2 3 5 3 4 1 M23 Power Connector RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 15 ...
Page 25: ...ne to Ground Transient Protection All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground All line to ground transient protection circuitry will be disabled Figure 2 9 Surge Ground Chassis Ground Connection 16 RUGGEDCOM M969 Installation Manual 01 2021 C79...
Page 26: ...temporary connection during initial configuration or troubleshooting Connection to the console port is made using an M12 to DB9 console cable The following is the pin out for the console port 2 4 1 3 5 7 6 8 Figure 3 1 M12 Console Port Pin Configuration Pin Name Description 1 Reserved Do Not Connect 2 RX Receive Data from DTE 3 TX Transmit Data from DTE 4 Reserved Do Not Connect 5 GND Common Groun...
Page 27: ...device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RUGGEDCOM M969 interface For more information about configuring the device refer to the RUGGEDCOM RUGGEDCOM M969 User Guide associated with the installed software release 18 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 28: ...le available through RUGGEDCOM M969 For more information on how to access the factory data file refer to the RUGGEDCOM M969 User Guide for the RUGGEDCOM M969 Each communication port type has a specific place in the RUGGEDCOM M969 chassis 2 1 1 M12 D Coded Copper Ethernet Ports 2 Fiber Optic Ethernet Ports Figure 4 1 Port Assignment M12 Connectors Shown RUGGEDCOM M969 Installation Manual 01 2021 C7...
Page 29: ...air UTP cables with RJ45 male connectors or M12 male connectors The RJ45 M12 connectors are directly connected to chassis ground on the device and can accept CAT 5 shielded twisted pair STP cables WARNING Electric shock hazard risk of serious personal injury and or equipment interference If shielded cables are used make sure the shielded cables do not form a ground loop via the shield wire and the...
Page 30: ...ata 7 Reserved Do Not Connect 8 Reserved Do Not Connect Pin Out M12 The following is the pin out description for the M12 connectors Figure 4 4 4 Pin D Coded M12 Ethernet Port Pin Configuration Pin 10 100Base Tx Signal 1 TX 2 RX 3 TX 4 RX Specifications For specifications on the available copper Ethernet ports refer to Copper Ethernet Port Specifications Page 23 4 2 Fiber Optic Ethernet Ports Fiber...
Page 31: ...Ports 2 1 1 Tx Connector 2 Rx Connector Figure 4 5 LC Port For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Ethernet Port Specifications Page 24 22 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 32: ...HI 110 230 VAC b 85 VAC 265 VAC 3 15A T a 5 5 kVDC 10 W a T denotes time delay fuse b This is the same power supply for both AC and DC 5 2 Failsafe Alarm Relay Specifications Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 A 62 5 W 1500 Vrms for 1 minute 5 3 Copper Ethernet Port Specifications Dat...
Page 33: ...ied Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances All optical power numbers are listed as dBm averages To convert from average to peak add 3 dBm To convert from peak to average subtract 3 dBm Tx dBm Mode Connector Cable Type µm Tx λ nm a Min Max Rx Sensi...
Page 34: ...GGEDCOM M969 enclosure b Reduced to 40 to 80 C 40 to 76 F when equipped with a 100Base FX single mode 1300 nm long reach 90 km port s c Non condensing d Over temperature range of 40 to 85 C 40 to 185 F 5 6 Mechanical Specifications Weight 2 86 kg 6 3 lb Ingress Protection IP67 Enclosure Cast Aluminum 5 7 Dimension Drawings Note All dimensions are in inches unless otherwise stated RUGGEDCOM M969 In...
Page 35: ...Technical Specifications 5 7 Dimension Drawings Figure 5 1 8 RJ45 IP67 Ethernet Ports and M23 Power 26 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 36: ...Technical Specifications 5 7 Dimension Drawings Figure 5 2 8 M12 D Code Ethernet Ports and M23 Power RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 27 ...
Page 37: ...Technical Specifications 5 7 Dimension Drawings 28 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 38: ...ption M23 5pin female connector 600V IP68 rated Order Code 99 60 0007 Cable Specifications 3 18 AWG jacket OD range 0 20 0 48 M23 Power Cable Description Overmold R A M23 plug to free end 5m yellow PUR jacket for dual power supply Order Code 99 43 0129 001 Cable Specifications Overmold R A M23 plug to free end 5 m RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 29 ...
Page 39: ...e Description M12 8pin A code male to DB9 female unshielded PUR jacket cable 30V 4A 3m Order Code 99 43 0023 001 Cable Specifications M12 8pin A code male to free end 3m M12 Console Port Mating Connector Description M12 straight plug 8 pole A coded IP67 rated Order Code 99 60 0002 30 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 40: ...ting Cable Figure 6 5 M12 FailSafe Port Mating Cable Description M12 4pole A coded unshielded PUR Jacket cable 3m Order Code 99 43 0024 001 M12 FailSafe Port Mating Connector Description M12 straight plug 4 pole A coded IP67 rated Order Code 99 60 0009 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 31 ...
Page 41: ...2 D code Ethernet Port Mating Cable Description M12 D code to RJ45 patch cable 3meters Order Code 99 43 0040 001 Cable Specifications M12 D code male 4 pin CAT5e 3m M12 D code Ethernet Port Mating Connector Description M12 straight plug 4 pole D coded IP67 rated Order Code 99 60 0008 32 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 42: ... code to male D code shielded PUR jacket patch cable 5 meters Order Code 99 43 0041 001 Cable Specifications M12 male 4 pin CAT 5e 5m IP67 Metal RJ45 Ethernet Port Mating Cable Figure 6 10 IP67 Metal RJ45 Ethernet Port Mating Cable Description IP67 Metal RJ45 plug to RJ45 CAT5e shielded patch cable 3m Order Code 99 43 0182 001 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 33 ...
Page 43: ...rt Mating Connector Figure 6 12 IP67 Metal RJ45 Ethernet Port Mating Connector Description IP67 Metal RJ45 plug field attachable Order Code 99 60 0010 IP67 Metal RJ45 Ethernet Port Mating Cable Figure 6 13 IP67 Metal RJ45 Ethernet Port Mating Cable Description IP67 Metal RJ45 plug on both ends Category 5e shielded patch cable 3m Order Code 99 43 0039 001 34 RUGGEDCOM M969 Installation Manual 01 20...
Page 44: ...e 3meters IP67 rated Order Code 99 43 0057 001 Figure 6 15 LC Port Mating Connector Description Cable Singlemode Metal IP67 LC to LC Singlemode fiber cable 3 meters IP67 rated Order Code 99 43 0055 001 Description Cable Multimode Metal IP67 LC to Metal IP67 LC Multimode fiber cable 3meters IP67 rated Order Code 99 43 0047 001 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 35 ...
Page 45: ...3 0053 001 LC Port Mating Connector Figure 6 18 LC Port Mating Connector Description Cable Multimode Metal IP67 LC to Metal IP67 LC Multimode fiber cable 3meters IP67 rated Order Code 99 43 0047 001 Figure 6 19 LC Port Mating Connector Description Cable Singlemode Metal IP67 LC to Metal IP67 LC Singlemode fiber cable 3 meters IP67 rated Order Code 99 43 0053 001 36 RUGGEDCOM M969 Installation Manu...
Page 46: ...sories 6 5 LC Fiber Optic 2 unit LC RJ45 Port Cap Figure 6 20 LC RJ45 Port Cap Description RJ45 outlet cap IP67 Metal Order Code 99 60 0011 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 37 ...
Page 47: ...Accessories 6 5 LC Fiber Optic 2 unit 38 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 48: ...62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 7 1 2 European Commission EC This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EC directives EN 60950 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Stan...
Page 49: ...nd can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference on his own expense 7 1 4 FDA CDRH This device meets the requirements of the f...
Page 50: ...ection 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is marked with an RCM symbol to indicate compliance when sold in the Australian region A copy of the Declaration of Conformity is available via Siemens Industry Online Support at https support industry si...
Page 51: ...er Assemblies with NTCIP Requirements MIL S 901D MIL S 901D Military Specification Shock Tests H I High Impact Shipboard Machinery Equipment and Systems Requirements For 7 2 MIL STD Test Specifications Test Description MIL STD 167 Vibration Navy MIL STD 167 1 Type I CE101 DC 28V CE102 AC 115V RE101 RE102 1 Surface Ship Applications RE102 2 Submarine Applications Internal RE102 3 AirCraft and Space...
Page 52: ... the following EMC and environmental tests IEC 61850 3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact 8 kV 4 IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure ports 20 V m x Signal ports 4 kV 2 5 kHz x DC Power ports 4 kV 4 AC Power ports 4 kV 4 IEC 61000 4 4 Burst Fast Transient Earth ground ports 4 kV 4 Signal ports 4 kV line to earth 2 kV li...
Page 53: ...2 kV Fail Safe Relay output DC Power ports 1 5 kV IEC 60255 5 Dielectric Strength AC Power ports 2 kV Signal ports 5 kV Fail Safe Relay output DC Power ports 5 kV IEC 60255 5 HV Impulse AC Power ports 5 kV IEEE 1613 Type Tests Note If the unit contains copper ports the IEEE 1613 conformance is Class 1 during disturbance errors may occur but recovery is automatic If the unit contains all fiber port...
Page 54: ... severe transportation conditions Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60255 21 1 Vibration 2g 10 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 IEC 60529 IPx6 Ingress Protection Water...
Page 55: ...Certification 7 3 EMC and Environmental Type Tests 46 RUGGEDCOM M969 Installation Manual 01 2021 C79000 G8976 1039 03 ...
Page 56: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...