background image

Certification
6.1.7 ISO

6.1.7

ISO

This device was designed and manufactured using a certified ISO (International

Organization for Standardization) quality program that adheres to the following

standard:

ISO 9001:2015

Quality management systems – Requirements

6.1.8

ACMA

This device meets the requirements of the following Australian Communications and

Media Authority (ACMA) standards under certificate ABN 98 004 347 880:
• Radiocommunications (Compliance Labelling – Devices) Notice 2014 made

under Section 182 of the Radiocommunications Act 1992

• Radiocommunications Labelling (Electromagnetic Compatibility) Notice 2008

made under Section 182 of the Radiocommunications Act 1992

• Radiocommunications (Compliance Labelling – Electromagnetic Radiation)

Notice 2003 made under Section 182 of the Radiocommunications Act 1992

• Telecommunications Labelling (Customer Equipment and Customer Cabling)

Notice 2001 made under Section 407 of the Telecommunication Act 1997

The device is marked with an RCM symbol to indicate compliance when sold in the

Australian region.

A copy of the Declaration of Conformity is available via Siemens Industry Online

Support at 

https://support.industry.siemens.com/cs/ww/en/view/89855782

.

6.1.9

RoHS

This device is declared by Siemens AG to meet the requirements of the following

RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain

hazardous substances in electrical and electronic equipment:

China RoHS 2

Administrative Measure on the Control of Pollution Caused by Electronic

Information Products

A copy of the Material Declaration is available online at 

https://

support.industry.siemens.com/cs/ww/en/view/109738831

.

26

RUGGEDCOM i800

Installation Manual, 01/2021, C79000-G8976-1002-06

Summary of Contents for SIMATIC NET RUGGEDCOM i800

Page 1: ...Edition 01 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM i800 https www siemens com ...

Page 2: ...ged Ethernet Switches RUGGEDCOM i800 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 01 2021 C79000 G8976 1002 06 ...

Page 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Page 4: ...evice 6 2 4 Connecting the Failsafe Alarm Relay If Equipped 8 2 5 Connecting Power 9 3 Device Management 13 3 1 Connecting to the Device 13 3 2 Configuring the Device 14 3 3 Inserting Removing the MicroSD MicroSDHC Card 14 4 Communication Ports 17 5 Technical Specifications 19 5 1 Power Supply Specifications 19 5 2 Failsafe Alarm Relay Specifications 19 5 3 Copper Ethernet Port Specifications 19 5...

Page 5: ... 24 6 1 3 European Union EU 24 6 1 4 FCC 25 6 1 5 FDA CDRH 25 6 1 6 ISED 25 6 1 7 ISO 26 6 1 8 ACMA 26 6 1 9 RoHS 26 6 1 10 Other Approvals 27 6 2 EMC and Environmental Type Tests 27 iv RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 6: ...red Trademarks RUGGEDCOM and ROS are trademarks of Siemens AG Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years from the date of purchase conditional upon the return to factory for maintenance during the warranty term This product contains...

Page 7: ...ed with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical...

Page 8: ...y Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 vii ...

Page 9: ...Preface Contacting Siemens viii RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 10: ...40 F or optionally 40 to 85 C 40 to 185 F coupled with hazardous location certification Class 1 Division 2 allows the RUGGEDCOM i800 to be placed in almost any location The RUGGEDCOM i800 features a full array of intelligent functionality for high network availability and manageability The embedded Rugged Operating System ROS provides advanced Layer 2 and Layer 3 networking functions and advanced ...

Page 11: ...ory Options Removable microSD microSDHC card Power Supply Dual low voltage DC inputs 24 VDC 9 32 VDC Compression fit connections CSA UL 60950 safety approved to 85 C 185 F 1 2 Description The RUGGEDCOM i800 features various ports controls and indicator LEDs on the front panel for connecting configuring and troubleshooting the device 4 5 7 8 6 2 1 3 1 Failsafe Alarm Relay 2 Power Supply Terminal Bl...

Page 12: ...HC slot Use a microSD microSDHC card to load store the firmware and configuration for the device For information about using a microSD microSDHC card refer to Inserting Removing the MicroSD MicroSDHC Card Page 14 RS 232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about connecting to the device via the s...

Page 13: ...een fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulations 4 RUGGEDCOM i800 Installation Manual ...

Page 14: ...edures other than those specified herein may result in hazardous radiation exposure NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the eq...

Page 15: ...packing the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included IMPORTANT If any item is missing or damaged contact Siemens for assistance 2 3 Mounting the Device The RUGGEDCOM i800 can be ordered with a DIN rail adapter pre installed on the back of the chassis Use the adapter...

Page 16: ...o the following 1 Hook the top teeth of the adapter onto the DIN rail 2 2 3 1 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screw driver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail then let go of the sliding release to latch the device RUGGEDCOM i800 Installation Manual 01 2021 C7900...

Page 17: ...ailsafe relay can be configured to latch based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM i800 One common applicat...

Page 18: ...nal voltage to be connected To connect power to the device do the following NOTICE Terminals P1 P2 and GND are connected together internally As such if redundant power supplies are connected their negative terminals must be at the same potential Do not field wire the DC power supply on the DC mains or Battery mains Use minimum 16 gage wiring when connecting terminal blocks Equipment must be instal...

Page 19: ...erminal block 1 2 3 4 1 Positive Terminal 2 Negative Terminal 3 GND Terminal 4 Chassis Ground Terminal Figure 2 4 Terminal Block Wiring Single DC Power Supply Input 2 Connect the negative wire from the power source to the negative terminal P1 or P2 on the terminal block 10 RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 20: ...ng sure to connect the power supply to the P2 ports 1 2 1 2 3 4 1 Positive Terminal 2 Negative Terminal 3 GND Terminal 4 Chassis Ground Terminal Figure 2 5 Terminal Block Wiring Dual DC Power Supply Inputs 4 Connect the chassis ground terminal to protective Earth RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 11 ...

Page 21: ...Installing the Device 2 5 Connecting Power 12 RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 22: ...t provides access to RUGGEDCOM i800 s console and Web interfaces NOTICE The console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Desc...

Page 23: ...uration management is done via the RUGGEDCOM i800 interface For more information about configuring the device refer to the RUGGEDCOM ROS Configuration Manual associated with the installed software release 3 3 Inserting Removing the MicroSD MicroSDHC Card The RUGGEDCOM i800 accepts a microSD microSDHC card to support the following features Configuration update and backup Redundant firmware image Gr...

Page 24: ...vice or sending the device to a third party To insert or remove a microSD microSDHC card do the following 1 Power down the device 2 Unscrew the retention screw and remove the access plate 1 2 3 1 Retention Screw 2 Access Plate 3 MicroSD MicroSDHC Card Figure 3 2 Inserting Removing a MicroSD MicroSDHC Card 3 Without touching the contacts on the card insert or remove the microSD microSDHC card 4 Ins...

Page 25: ...Device Management 3 3 Inserting Removing the MicroSD MicroSDHC Card 16 RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 26: ...ent interference If shielded cables are used make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end Ground loops can cause excessive noise and interference but more importantly create a potential shock hazard that can result in serious injury Each port features a Speed and Link LED that indicates the state of the port LED State Descriptio...

Page 27: ... RX Receive Data 2 RX Receive Data 3 TX Transmit Data 4 Reserved Do Not Connect 5 Reserved Do Not Connect 6 TX Transmit Data 7 Reserved Do Not Connect 8 Reserved Do Not Connect For specifications on the available copper Ethernet ports refer to Copper Ethernet Port Specifications Page 19 18 RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 28: ...olation 30 VDC 2 A 60 W 125 VDC 0 24 A 30 W 125 VAC 0 5 A 62 5 W 220 VDC 0 24 A 60 W 250 VAC 0 25 A 62 5 W 1500 Vrms for 1 minute 5 3 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM i800 Speed Connector Duplex a Cable Type b Wiring Standard c Maximum Distance d Isolation e 10 100Base TX RJ45 FDX HDX Categ...

Page 29: ... Relative Humidity b up to 95 Maximum Altitude 2000 m 6562 ft Vibration 1 g 10 to 500 Hz Shock 30 g 11 ms a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Non condensing 55 C 131 F 6 cycles 5 5 Mechanical Specifications Weight 1 0 kg 2 2 lbs Ingress Protection IP40 1 mm or 0 04 in objects Enclosure Cast Aluminum Enclosure 5 6 Dimension Drawings Note All dimensions are...

Page 30: ...Technical Specifications 5 6 Dimension Drawings 134 5 117 5 56 5 95 3 77 5 11 7 6 3 22 84 97 4 112 3 Figure 5 1 Overall Dimensions RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 21 ...

Page 31: ...Technical Specifications 5 6 Dimension Drawings 22 RUGGEDCOM i800 Installation Manual 01 2021 C79000 G8976 1002 06 ...

Page 32: ...2 2 No 62368 1 14 Information Technology Equipment Safety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 14 05 Industrial Control Equipment CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 M1987 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations ...

Page 33: ...s IEC EN 60079 15 2005 Electrical Apparatus for Explosive Gas Atmospheres Part 15 Construction Test and Marking of Type of Protection N Electrical Apparatus It is specifically approved for use in hazardous locations defined as EEx nC IIC T4 Ex II 3 G 12 24 VDC 2A Class III 6 1 3 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisi...

Page 34: ...o frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense NOTICE Changes or modifications not expressly approved by the party responsibl...

Page 35: ...ection 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is marked with an RCM symbol to indicate compliance when sold in the Australian region A copy of the Declaration of Conformity is available via Siemens Industry Online Support at https support industry si...

Page 36: ...IEC 61000 4 5 Surge DC Power ports 0 5 kV line to earth line Signal ports DC Power ports IEC 61000 4 6 Induced Conducted RFI Earth ground ports 10 V IEC 61000 4 8 Magnetic Field Enclosure ports 30 A m IEC 61000 4 29 Voltage Dips DC Power ports 30 reduction for 0 3 seconds 60 reduction for 1 second Signal ports 2 5 kV common 1 kV differential mode 1 MHz IEC 61000 4 12 Damped Oscillatory DC Power po...

Page 37: ...rts 2 5 kV common 1 kV differential mode 1MHz Environmental Type Tests Test Description Test Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60068 2 6 Vibration 1 g 10 500 Hz IEC 60068 2 27 Shock 30 g 11 ms 28 RUGGEDCOM i800 Installation Man...

Page 38: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...