Connection
Connection
Connecting devices with 100 to 240 VAC power
supply
Switches for the input voltage
The socket X1 (position
①
) and the switch S1 Power (position
③
) for the input
voltage are located on the right-hand side of the front panel of the housing:
1
2
3
CAUTION
Connect and disconnect the power supply unit only when it is not energized!
The PS598-1 is not capable of hot plugging. Connecting or disconnecting the
PS598-1 when the 100 to 240 VAC power supply is on can damage the PS598-1
and the SCALANCE XR-500M.
Before connecting or disconnecting the PS598-1, make sure that the switch for the
input voltage is set to position "0".
Note
Fuses in the fuse holder
The fuses FUSE1 and FUSE2 are in the fuse holder (position
②
). The fuses are of
the type F6.3A / 250 VAC.
Power supply PS598-1 for SCALANCE XR-500M
A5E03275848A-01, 09/2011