background image

Mounting 

 

Power supply PS598-1 for SCALANCE XR-500M 

14

 

A5E03275848A-01, 09/2011 

On the rear panel of a SCALANCE XR-500M, there are sockets for the direct 

connection of a maximum of two PS598-1 power supply units. On the rear of the 

PS598-1 there is a corresponding plug. Follow the steps below to install the PS598-1 

on the rear panel of a SCALANCE XR-500M: 
1.

 

Fit the PS598-1 and the SCALANCE XR-500M together. The two devices are 

equipped with positioning elements that must engage during installation and 

protect the plug from excessive bending strain. 

2.

 

Screw the two devices to the mounting plates supplied with the main device. The 

maximum tightening torque of the screws is 0.5 Nm. 

Summary of Contents for SIMATIC NET PS598-1

Page 1: ...Power supply PS598 1 for SCALANCE X 500 English A5E03275848A 01 s SIMATIC NET 09 2011 A5E03275848A 01 SIEMENS AG 2011 Technical data subject to change Compact operating instructions ...

Page 2: ......

Page 3: ... 8 Unpacking and checking 9 Mounting 10 19 rack mounting of the PS598 1 10 Mounting the PS598 1 on the rear panel of an XR 500M 12 Connection 15 Connecting devices with 100 to 240 VAC power supply 15 Upkeep and maintenance 20 Changing the air filter 20 Technical data 21 Mechanical and electrical data 21 Dimension drawings 23 Approvals 24 EMC directive 24 Mechanical stability in operation 26 ...

Page 4: ... hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used these must be recommended or approved by Siemens Proper transport storage installation assembly commissioni...

Page 5: ...utions are not taken WARNING indicates that death or severe personal injury may result if proper precautions are not taken CAUTION with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken CAUTION without a safety alert symbol indicates that property damage can result if proper precautions are not taken NOTICE indicates that an unintended result...

Page 6: ...operating instructions you will be able to install and connect up the PS598 1 correctly Validity of these compact operating instructions These compact operating instructions apply to the product PS598 1 as of product version 1 Power supply PS598 1 for SCALANCE XR 500M 6 A5E03275848A 01 09 2011 ...

Page 7: ...evices with this mark have a 100 to 240 VAC power supply This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Connecting and disconnecting may only be performed by an electrical specialist Connect or disconnect power supply cables only when the power is turned off General notices WARNING Opening th...

Page 8: ...oltage 24 VDC Note that you can only use one connector on the front or the connector on the rear of the PS598 1 You cannot operate the device with the connectors on the front and rear at the same time Note Requirement for connecting at the rear Note that the connector on the rear of the PS598 1 can only be used if the power supply is mounted on the SCALANCE XR 500M Power supply PS598 1 for SCALANC...

Page 9: ...W 6GK5 598 1AA00 3AA0 Note Replacing the filter mat To replace the filter mat use the material Viledon P 15 150 G2 EN 779 The dimensions of the filter mat are 38 x 135 x 8 mm H x W x D Unpacking and checking 1 Make sure that the package is complete 2 Check all the parts for transport damage WARNING Do not use any parts that show evidence of damage If the consignment is incomplete or if there is da...

Page 10: ...ice due to inadequate cooling If the ventilation grilles are fully or partly covered or the air filters are contaminated the temperature inside the housing can rise and exceed the maximum permitted temperature and damage the device During installation select a mounting position so that the ventilation grilles are always free so that the air can circulate The ventilation grilles are located on the ...

Page 11: ...e the two mounting brackets with four screws each M3 x 6 supplied with the product to the side panels of the power supply unit The maximum tightening torque for these screws is 0 5 Nm 2 Screw the PS598 1 to the 19 rack Power supply PS598 1 for SCALANCE XR 500M A5E03275848A 01 09 2011 11 ...

Page 12: ...using can rise and exceed the maximum permitted temperature and damage the device During installation select a mounting position so that the ventilation grilles are always free so that the air can circulate The ventilation grilles are located on the side panels of the housing You will find information about cleaning the air filter in the section Upkeep and maintenance Power supply PS598 1 for SCAL...

Page 13: ...Mounting Procedure Power supply PS598 1 for SCALANCE XR 500M A5E03275848A 01 09 2011 13 ...

Page 14: ...ere is a corresponding plug Follow the steps below to install the PS598 1 on the rear panel of a SCALANCE XR 500M 1 Fit the PS598 1 and the SCALANCE XR 500M together The two devices are equipped with positioning elements that must engage during installation and protect the plug from excessive bending strain 2 Screw the two devices to the mounting plates supplied with the main device The maximum ti...

Page 15: ...ly when it is not energized The PS598 1 is not capable of hot plugging Connecting or disconnecting the PS598 1 when the 100 to 240 VAC power supply is on can damage the PS598 1 and the SCALANCE XR 500M Before connecting or disconnecting the PS598 1 make sure that the switch for the input voltage is set to position 0 Note Fuses in the fuse holder The fuses FUSE1 and FUSE2 are in the fuse holder pos...

Page 16: ...Connection Pin assignment of the X2 socket on the front L M M L Contact Assignment L 24 VDC M Ground M Ground L 24 VDC Power supply PS598 1 for SCALANCE XR 500M 16 A5E03275848A 01 09 2011 ...

Page 17: ... Connector X3 is located on the back of the PS598 1 Connector X3 is intended only to connect the PS598 1 directly to an XR 500M L L L M M M Contact Assignment L L L 24 VDC M M M Ground Power supply PS598 1 for SCALANCE XR 500M A5E03275848A 01 09 2011 17 ...

Page 18: ...CE XR 500M and the PS598 1 units with one cable for 24 VDC and a cable for ground As an alternative you can also mount the two PS598 1 units on the back of the SCALANCE XR 500M and secure them with screws In this case no extra cables are necessary You will find detailed information in the section Mounting Page 10 It is also possible to operate the SCALANCE XR 500M even after the failure of a PS598...

Page 19: ...S598 1 units share the applied load automatically and uniformly Note Two connectors for the 24 VDC output voltage The PS598 1 has two connectors with the output voltage 24 VDC Note that you can only use the connector on the front or the connector on the rear of the PS598 1 You cannot operate the device with the connectors on the front and rear at the same time LED display A PS598 1 has two LEDs ea...

Page 20: ...Open the service panel 2 Take the air filter out of the device 3 Clean the air filter 4 Place the cleaned air filter in the device again 5 Close the panel CAUTION A badly contaminated air filter reduces air flow and can cause the device to be damaged Check the degree of contamination of the air filter regularly and clean it when necessary Power supply PS598 1 for SCALANCE XR 500M 20 A5E03275848A 0...

Page 21: ...r of the housing for direct connection to a SCALANCE XR 500M Construction Dimensions without brackets for rack mounting W x H x D 446 x 44 x 140 mm 1 height unit Weight 1700 g Surface of the housing Powder coating Degree of protection IP20 with closed panel in housing Installation in a 483 mm rack 19 rack Yes DIN rail mounting No S7 300 standard rail mounting No Wall mounting No Power supply PS598...

Page 22: ...on of the power supply F6 3 A 250 VAC Environmental conditions Transportation storage temperature 40 C to 85 C Operating temperature 0 C to 60 C Maximum relative humidity in operation at 25 C 95 no condensation Operating altitude above sea level depending on ambient temperature 2000 m at max 56 C 3000 m at max 50 C Power supply PS598 1 for SCALANCE XR 500M 22 A5E03275848A 01 09 2011 ...

Page 23: ...Technical data Power supply PS598 1 for SCALANCE XR 500M A5E03275848A 01 09 2011 23 Dimension drawings View from front and above 140 170 44 446 Dimensions are specified in mm ...

Page 24: ... NET products described in these operating instructions meet the requirements of EC directive 2004 108 EC Electromagnetic Compatibility for the following areas of application Requirements Field of application Emission Immunity to interference Industry EN 61000 6 4 2007 EN 61000 6 2 2005 Note for Australia The product meets the requirements of the AS NZS 2064 standard Class A WARNING Personal injur...

Page 25: ...product from electrostatic discharge personnel must first discharge any electrostatic charge from their body before touching the product Note The product was tested with a device that also complies with the standards listed above If the product is operated with a device that does not meet these standards there is no guarantee that the corresponding values will be adhered to Low voltage equipment d...

Page 26: ...tave min 20 sweeps 15 g 11 ms duration 6 shocks per axis 10 58 Hz 0 075 mm 85 150 Hz 1 g 1 octave min 20 sweeps PS598 1 Note When rack mounted with four securing points P Trademarks All names identified by are registered trademarks of Siemens AG The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Dis...

Reviews: