3.3
Connecting the device
3.3.1
Country-specific information on supply voltage
Country-specific information on supply voltage for USA and Canada
Supply voltage 120 V / 230 V / 240 V
Ensure that the power cords used are rated for the maximum current input and ambient
temperature of the device and meet the requirements of the following standards:
•
ANSI/UL 817
•
CSA C22.2 No. 21
Ensure that the device connectors, connection sockets and connection materials are rated for
the maximum current input and ambient temperature of the device and meet the
requirements of the following standards:
•
ANSI/UL 498 and CSA C22.2 No. 42
•
CSA C22.2 No. 182.1
•
CSA C22.2 No. 182.2
•
CSA C22.2 No. 182.3
Country-specific information on supply voltage for outside of USA and Canada
Supply voltage 230 V AC
This device is supplied with a safety-tested power cord and may only be connected to a
grounded SCHUKO socket outlet.
If you do not use the power cord, use a flexible cable that is rated for the maximum current
input and ambient temperature of the device and complies with the safety regulations of the
country in which the device is installed.