Expanding and assigning parameters to the device
6.6 Installing and removing drives
118
Operating Instructions, 01/2021, A5E43920357-AA
6.6.2.2
Change 2.5" and 3.5" drive in assembly kit for 5.25" tray
You can install 2.5" and 3.5" drives in the assembly kit for the 5.25" tray in the drive cage type
A and the drive cage type B.
In this assembly kit, the drive is shock and vibration dampened.
Assembly kit HDD/SSD for 5.25" tray
Requirement
•
You know the important safety instructions under "Safety instructions on device and
system extensions (Page 48)".
•
The device is equipped with a drive cage type B.
•
You know the information under:
–
Installation conditions for drives in drive cage type B (Page 115)
•
An original spare part, that is, an HDD/SDD assembly kit for 5.25" tray approved for this
device. For information on replacement parts, refer to "Hardware accessories (Page 35)".
•
When replacing a 3.5" HDD: T10 screwdriver
•
When replacing a 2.5" SSD: T8 screwdriver
Procedure
1.
Fully disconnect the device from the line voltage, see "Switching off the device (Page 72)".
2.
Open the device. Be sure to follow the important instructions under "Open the device
(Page 93)".
3.
Remove all power supply and data cables from the drive.