Readers
5.2 SIMATIC RF210M
SIMATIC RF200
98
System Manual, 07/2015, J31069-D0227-U001-A9-7618
5.2.5
Display elements of the RF210M reader
Color
Meaning
green flashing
Operating voltage present, reader not initialized or antenna switched off
permanently
lit
Operating voltage present, reader initialized and antenna switched on
yellow
1)
Transponder present
flashing red
Error has occurred, the type of flashing corresponds to the error code in the
table in the section "Error codes". The optical error display is only reset if the
corresponding reset parameter ("option_1 = 2") is set (see Product infor-
mation "SIMATIC RF200 command set"
https://support.industry.siemens.com/cs/ww/en/view/44864850
1)
Only in the "with presence" mode.
5.2.6
Technical specifications of the RF210M reader
Table 5- 2
Technical specifications of the RF210M reader
6GT2823-0AA00
Product type designation
SIMATIC RF210M
Radio frequencies
Operating frequency, rated value
13.56 MHz
Electrical data
Maximum range
20 mm
Maximum data transmission rate reader ↔ tra
n-
sponder (tag)
ISO tags
•
Read
•
approx. 1500 bytes/s
•
Write
•
approx. 1500 bytes/s
Typical transmission time for user data per byte
•
for write access
•
0.6 ms
•
for read access
•
0.6 ms
Baud rate
19200, 57600, 115200 Bd
Read/write distances of the reader
see section "Field data (Page 37)"
Interfaces
Electrical connector design
M8, 8-pin
Standard for interfaces for communication
RS-422
Antenna
integrated
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......