RF200 system planning
4.3 Installation guidelines
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
59
4.3.4.4
RF250R
The RF250R reader is operated with the external antennas ANT 3, 8, 12, 18 and 30. The
antennas can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 4-12 Metal-free space for ANT 8 / ANT 12 and ANT 18 / ANT 30
Table 4- 19 Reduction of field data due to metal, range as %: Transponder and RF250R with ANT 3
Transponder
RF250R with ANT 3
antenna without met-
al
antenna flush-
mounted in metal
(all round 20 mm)
MDS D124
1)
without metal
100
80
on metal, distance 15 mm
90
75
flush-mounted in metal;
distance all round 25 mm
75
70
MDS D126
1)
without metal
100
80
on metal, distance 25 mm
85
75
flush-mounted in metal;
distance all round 50 mm
60
50
MDS D160
1)
without metal
100
85
on metal, distance 10 mm
95
80
MDS D324
1)
without metal
100
80
on metal, distance 15 mm
95
75
flush-mounted in metal;
distance all round 25 mm
85
70
MDS D422
without metal
100
95
flush-mounted in metal;
distance all round 0 mm
95
80
MDS D423
without metal
100
90
on metal, distance 0 mm
130
2)
110
2)
flush-mounted in metal;
distance all round 10 mm
80
70
MDS D424
1)
without metal
100
85
on metal, distance 15 mm
90
75
flush-mounted in metal;
distance all round 25 mm
75
70
Summary of Contents for SIMATIC Ident
Page 1: ......
Page 2: ......
Page 14: ...Table of contents SIMATIC RF200 14 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 186: ...Antennas 6 8 ANT D10 SIMATIC RF200 186 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 300: ...Transponder 7 28 MDS D528 SIMATIC RF200 300 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 304: ...System integration SIMATIC RF200 304 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 358: ...Glossary SIMATIC RF200 358 System Manual 07 2015 J31069 D0227 U001 A9 7618 ...
Page 362: ......