background image

 

 

 

House Control with 
LOGO! 8 and 

Weather Sensors 

 

LOGO! 8, KTP400  
Set 11 

 

https://support.industry.siemens.com/cs/ww/en/view/68585346 

 

 

 

Siemens 
Industry 
Online 

Support 

Summary of Contents for SIMATIC HMI KTP400 Basic

Page 1: ...House Control with LOGO 8 and Weather Sensors LOGO 8 KTP400 Set 11 https support industry siemens com cs ww en view 68585346 Siemens Industry Online Support ...

Page 2: ...laims for damages arising from a breach of material contractual obligations shall however be limited to the foreseeable damage typical of the type of agreement unless liability arises from intent or gross negligence or is based on loss of life bodily injury or damage to health The foregoing provisions do not imply any change in the burden of proof to your detriment You shall indemnify Siemens agai...

Page 3: ...P400 14 4 1 2 LOGO 8 14 4 1 3 Assigning IP addresses to LOGO and setting the master mode 15 4 2 Software installation download 15 4 3 Commissioning 16 4 3 1 Basic settings for the KTP400 16 4 3 2 Settings in the operating system 19 4 3 3 Assigning devices and programs 20 4 3 4 Loading the programs into the KTP400 and KTP700 20 4 3 5 Configuring dynamic warning messages for wind in the KTP700 WinCC...

Page 4: ...n In a residential home the following functions shall be controlled automatically using weather sensors and the measuring values displayed on a Basic Panel Blinds and Roof hatch up down Interior and exterior lighting on off Heating Garden watering Figure 1 1 Roof hatch up down Interior light on off Blinds up down Exterior light on off Central light on off Blinds up down Heizung PT 100 WARNING Risk...

Page 5: ...t 11 Entry ID 68585346 V2 1 09 2018 5 Siemens AG 2018 All rights reserved 2 Solution 2 1 Overview Schematic layout The figure below shows a schematic overview of the most important components of the solution Figure 2 1 PROFINET IE Set 9 10 Set 11 1 2 3 4 ...

Page 6: ...nd Touch Panel Individually setting each of the blinds also possible in automatic mode Minimizing wind damage at the blinds Cost reduction through efficient room temperature with internal and external temperature comparison Additional option to control the functionalities of the application on the PC via the WinCC Basic Panel simulation function 2 2 Hardware and software components Note Please not...

Page 7: ...ngler rain sensor RS 600 6 Temperature sensor Measuring range 20 C 40 C Output voltage 0 10V DC Operating voltage 12 24V DC 1 Available from specialist retailers e g Stengler temp sensor TS S 7 Twilight sensor Measuring range 0 255 Lux linear Output voltage 0 10V DC Operating voltage 12 24V DC 1 Available from specialist retailers e g Stengler twilight sensor DS S 8 Light sensor Measuring range 0 ...

Page 8: ...ation from LOGO Set 11 a revised WinCC V15 project for the KTP700 from LOGO Set 10 a WinCC V15 project for the KTP400 of the weather station from LOGO Set 11 A LOGO Web project for the user defined webserver Note Please note that the LOGO program and the WinCC project from LOGO Set 10 have been expanded here by the following functions Weather sensor data processing Weather dependent panel alarm me...

Page 9: ...with the respective block name using the LOGO display or LOGO TDE This makes it possible to adjust the threshold values for the wind speed for opening the blinds When wind speeds fall below 18 km h the LOGO program signals that the wind has died down and the blinds can be moved down again Note For wind velocities below the limit value here 18 km h the blinds will be raised in the morning and lower...

Page 10: ...e morning at 09 00 a m and in the evening at 08 00 p m for 10 minutes via the function block watering B104 Weekly Timer If automatic mode for the roof hatch has been activated it will automatically close when it rains If it does not rain and the temperature is high the roof hatch will open The function block watering can be called up in parameter assignment mode with the respective block name usin...

Page 11: ...ces will be configured automatically In addition it is possible to display three programs at once and to drag drop signals from one program to the other 3 2 1 Creating a project in network view and two way programming Adding a device in network view Table 3 1 No Action response LOGO Soft Comfort V8 1 Start LOGO Soft Comfort V8 2 Click on Network project tab to open the network project view 3 Click...

Page 12: ...0BA8 devices Table 3 2 No Action response LOGO Soft Comfort V8 1 A double click on one of the LOGO base modules in the network view automatically opens the switching program in the diagram editor of the network project 2 To exchange data between two LOGO devices open the switching programs of two LOGO devices 3 Now click on the symbol for dividing the diagram editor in two windows in order that an...

Page 13: ...ock you want to connect the first function block with When you release the mouse button LOGO Soft Comfort V8 will connect both function blocks 6 Once both function blocks are connected LOGO Soft Comfort V8 will create a function block pair and an Ethernet connection and a data transfer mechanism When the function blocks are displayed in green configuration of the communication between the two LOGO...

Page 14: ...bles 4 1 1 KTP400 Note Observe the setup guidelines for the KTP400 Further information can be found in the KTP400 Basic Panel Manual IP addresses and subnet masks Make sure that the KTP400 your PC and the hardware setup from LOGO Set 9 and LOGO Set 10 are in the same IP address range as shown in the following table Table 4 2 No Device IP address Subnet mask 1 KTP400 weather station Set 11 192 168 ...

Page 15: ...s the OK button of the LOGO controller and use the arrow keys C1 C2 C3 and C4 to enter your LOGO s IP address here 192 168 1 13 Confirm with the OK button 4 Press the ESC key to return to the previous menu item and select Set M S mode 5 For configuring the master LOGO select Master 6 The configuration of the IP address and the mode for the LOGO is now complete Press ESC to return to the main menu ...

Page 16: ...troller Settings for web server access For LOGO Set 9 refer to the following entry Building Automation Systems House control with LOGO and Master Slave communication LOGO Set 9 https support industry siemens com cs ww en view 64143308 4 3 1 Basic settings for the KTP400 Note The IP address of the HMI panel can only be changed if Runtime has been stopped Table 4 4 No Action response KTP400 display ...

Page 17: ...IP address 192 168 1 80 Subnet mask 255 255 255 0 4 Under Ethernet parameters in the Mode and speed selection field tick Auto Negotiation this automatically detects and sets the connection type and the transmission rate in the PROFINET network 5 Activate the LLDP switch to enable the operator panel to exchange information with other operator panels In this example LLDP can be activated or deactiva...

Page 18: ...sfer settings button to open the Transfer Settings dialog box 2 Activate Enable transfer 3 Activate Automatic to enable automatic transfer When automatic transfer is enabled a transfer from the configuration PC can be started while the project is running In this case the current project is stopped and the transfer of the new project is carried out After the transfer the new project is started 6 To...

Page 19: ...of the Application S7ONLINE STEP7 TCP IP Auto Name of your network card or your USB Ethernet adapter has been selected Click on OK to confirm the selection 3 Alternatively the Interface Parameter Assignment Used is displayed at Control Panel Set PG PC Interface for certain operating systems As in the previous step 2 also select the interface here and make sure that Access Point of the Application ...

Page 20: ...8_weather_station lsc contained in the network project 68585346_LOGO _Set11_LOGO _8 lnp 4 Master LOGO Set 9 68585346_LOGO _Set11_LOGO _8 lsc contained in the network project 68585346_LOGO _Set11_LOGO _v20 lnp 5 Slave LOGO Set 9 6 LOGO TDE Set 9 4 3 4 Loading the programs into the KTP400 and KTP700 Table 4 7 No Action response WinCC 1 Start WinCC and with Browse open the project 68585346_LOGO _ Set...

Page 21: ... 168 1 80 and press Enter to confirm Make sure that S7ONLINE is specified under Access point the master LOGO IP address is specified under PLC here 192 168 1 13 the check box Cyclic operation is ticked 5 In the project tree go to Devices networks and select it with a double click 6 Make sure a subnet has been added to the network To create a subnet in the network open the context menu with a right...

Page 22: ... IP address 192 168 1 80 Subnet mask 255 255 255 0 8 In the project tree select the folder KTP400 Basic PN and click on Load in the toolbar 9 Select the Ethernet interface of your network card or your USB Ethernet adapter with which you will connect your PC to the Basic Panel Then click on Load 10 Then confirm the dialog and then click on Load 11 As soon as the project download has been completed ...

Page 23: ...d 1 km h Weak wind Wind speed km h Blinds can still be operated 2 Moderate wind 20 km h Moderate wind Wind speed km h Blinds will remain closed 3 Fresh wind 30 km h Fresh wind Wind speed km h Blinds will remain closed 4 Strong wind 40 km h Strong wind Wind speed km h Blinds will remain closed Individually adjust and modify warning messages Warning message texts thresholds and colors can be modifie...

Page 24: ...Open the project view to open it 3 In the project tree under KTP700 KTP700 Basic PN go to HMI alarms and select it with a double click 4 Navigate to the Analog alarms tab The following options are provided 1 Trigger tag allows you to specify which tag to use for monitoring the threshold here for wind 2 Enter the limit value in Limit to define when a specific warning message is displayed 1 2 ...

Page 25: ... text where you would like to display a value 3 Open the context menu with a right click and select the menu item Insert tag field 6 Now select the tag you would like to display in the text and specify the number of digits to be displayed in the message Then click on the green checkmark to close the window 7 Now go to the Alarm classes tab Here you can assign user defined names to the individual w...

Page 26: ... Proceed as follows 1 Click on the Alarm window to open its properties 2 Go to the Properties tab and make sure that the warning messages here for wind which you have configured are enabled under Current alarm states and Unacknowledged alarms 10 Once you have completed all changes and modifications of the warning messages click Load in the toolbar to load the project to the KTP700 ...

Page 27: ...ave communication LOGO Set 9 https support industry siemens com cs ww en view 64143308 5 1 Monitoring with the KTP400 5 1 1 KTP400 screens All KTP screens have a uniform toolbar on the right Press one of the buttons to go to the following screens Start Weather System Support Language switching Note Synchronized language change from Basic Panel to LOGO 8 If the KTP400 is used to change the language...

Page 28: ...trol and Weather Sensors LOGO Set 11 Entry ID 68585346 V2 1 09 2018 28 Siemens AG 2018 All rights reserved 5 1 3 Overview of weather data Figure 5 2 This figure displays the current measured values from the weather sensors ...

Page 29: ...D 68585346 V2 1 09 2018 29 Siemens AG 2018 All rights reserved 5 1 4 System functions Figure 5 3 This screen provides system functions Clean screen Calibrate Data transfer Runtime Stop More information on the system functions can be found in the Basic Panel manual 4 ...

Page 30: ...r Sensors LOGO Set 11 Entry ID 68585346 V2 1 09 2018 30 Siemens AG 2018 All rights reserved 5 1 5 Online Support information Figure 5 4 Information on the Online Support can be found here The Home button 1 brings you back to the main menu ...

Page 31: ...KTP700 and KTP400 Table 5 1 No Action response KTP700 and KTP400 1 Verify on the KTP700 LOGO Set 10 that Automatic mode for the blinds is activated KTP700 2 The wind speed exceeds 20 km h KTP400 3 All blinds move up and stay in this final position for as long as the wind is strong 20 km h KTP700 4 The KTP700 displays a warning message that the wind speed has increased ...

Page 32: ... speed Note A total of 4 different warning messages have been configured for different wind speed levels in the WinCC project in this application example Older warning messages which have not been acknowledged remain on display in the alarm window even if the wind speed has changed or other warning messages have been activated KTP700 7 Press the button for acknowledging warning messages until the ...

Page 33: ...33 Siemens AG 2018 All rights reserved No Action response KTP700 and KTP400 8 Close the message window after you have cleared all warning messages KTP700 9 If the wind speed drops below 18 km h and at the same time there is high irradiation 20 kLUX all blinds will automatically close KTP400 ...

Page 34: ...el with the WinCC simulation For operating the application example with the PC the same basic settings chapter 4 3 1 in the WinCC project apply as for direct operation with the Basic Panel The only difference is that you do not press the Load button but the Start simulation button Table 5 2 No Action response WinCC 1 In the project tree select the folder KTP400 KTP400 Basic PN and click on Start s...

Page 35: ...on examples and videos all information is accessible with just a few mouse clicks https support industry siemens com SITRAIN Training for Industry We support you with our globally available training courses for industry with practical experience innovative learning methods and a concept that s tailored to the customer s specific needs For more information on our offered trainings and courses as we...

Page 36: ...ttps support industry siemens com cs ww en view 68585 346 3 LOGO 8 Manual https support industry siemens com cs ww en view 109741041 4 HMI KTP400 Manual https support industry siemens com cs ww en view 90114350 5 LOGO Software updates http w3 siemens com mcms programmable logic controller en logic module logo demo software Pages Default aspx 6 LOGO Application Examples http w3 siemens com mcms pro...

Reviews: