Operating Instructions (compact)
1.7 Installing/Mounting
SIMATIC HMI IPC577C
Operating Instructions (Compact), 05/2009, A5E02368077-01
13
1.7.3
Securing the Device with Clamps
You require 6 clamps in order to mount the device. These are supplied with the device.
Required tool for fasting the clamps: Allen wrench 2.5 mm
Figure 1-3
Clamp assembly
Rack installation
Steps for fastening the device with clamps
1. Follow the installation instructions.
2. Disconnect the device from the power supply.
3. Working from the front, insert the device into the 19" rack.
4. Fasten the control unit in the rack from the rear using the clamps. Tighten the setscrews to a
torque of 0.4-0.5 Nm.
Swivel arm installation
Steps for fastening the device with clamps
1. Follow the installation instructions.
2. Disconnect the device from the power supply.
3. Working from the front, place the device onto the swivel arm.
4. Fasten the control unit on the swivel arm from the rear using the clamps. Tighten the setscrews
to a torque of 0.4-0.5 Nm.
Control cabinet installation
Steps for fastening the device with clamps
1. Follow the installation instructions.
2. Disconnect the device from the power supply.
3. Working from the front, insert the device into the mounting cut-out.
4. Secure the control unit in the mounting cut-out from behind with the clamps, as shown in the
mounting cut-out in the dimensions. Tighten the setscrews to a torque of 0.4-0.5 Nm.
IP65 degree of protection
The IP65 degree of protection is only provided for a clamp mounting together with a ring
seal.