OPC UA communication
9.4 Using the S7-1500 CPU as an OPC UA client
Communication
264
Function Manual, 11/2019, A5E03735815-AH
12.
Click on the small black triangle next to "Objects".
STEP 7 now also displays the level below Objects.
13.
Click on the small black triangle next to "Productionline".
STEP 7 now also displays the level below Productionline.
14.
Now open additional lower-level folders:
Figure 9-67 Online view of OPC UA server interface
See also
Mapping of data types (Page 142)
Creating client interfaces (Page 251)
9.4.7
Using multilingual texts
In the client interface editor, you are also importing texts that can be displayed in different
languages with the OPC UA XML files (information models). Multilingualism is optional, and
each node can be defined differently regarding the languages it offers.
In the XML file, these are the following fields that can be prepared for different languages:
●
Display name
●
Description