background image

 

Introduction 

 

SIMATIC RTLS4060T 
Operating Instructions, 01/2021, C79000-G8976-C550-03 

7

 

Security recommendations 

General 

Note the following security recommendations to prevent unauthorized access: 

 

Keep the firmware up to date. Check regularly for security updates for the device. You can 

find information on this at the Industrial Security 

(

https://new.siemens.com/global/en/company/topic-areas/future-of-

manufacturing/industrial-security.html

) website. 

 

Inform yourself regularly about security recommendations published by Siemens 

ProductCERT (

https://new.siemens.com/global/en/products/services/cert.html

)

 

Evaluate your plant as a whole in terms of security. Use a cell protection concept with 

suitable products. 

 

This product requires an additional security concept to prevent unauthorized access. 

 

Transponder and infrastructure can be configured for radio channels according to IEEE 

802.15.4-2015. You will find details in the section 
"Technical specifications". 

 

Ensure that the radio frequencies are not used for other purposes and are not affected by 

other interfering signals. This should be ensured within the operating range of the 

localization system. 

 

Interference in the frequency band used can impair the system and, in extreme cases, lead 

to localization failure. 

Physical access 

 

Restrict physical access to the device to qualified personnel. 

 

Disable unused physical interfaces of the device. Unused interfaces could be used to gain 

access to the operating site. 

Recycling and disposal 

The products are low in harmful substances, can be recycled and meet the requirements of 

the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). 
Do not dispose of the products at public disposal sites. 
For environmentally compliant recycling and disposal of your electronic waste, please contact 

a company certified for the disposal of electronic waste or your Siemens representative. 
Note the different national regulations. 

Summary of Contents for SIMATIC 6GT2700-6DE03

Page 1: ...IMATIC RTLS Localization systems SIMATIC RTLS4060T Operating Instructions 01 2021 C79000 G8976 C550 03 Introduction 1 Device description 2 Installation Operation 3 Technical specifications 4 Approvals 5 ...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ... C79000 G8976 C550 03 3 Table of contents 1 Introduction 5 2 Device description 9 2 1 Characteristics 9 2 2 Order data RTLS4060T 9 2 3 Pin assignment 10 2 4 Dimension drawing 12 3 Installation Operation 13 4 Technical specifications 15 5 Approvals 17 ...

Page 4: ...Table of contents SIMATIC RTLS4060T 4 Operating Instructions 01 2021 C79000 G8976 C550 03 ...

Page 5: ...llowing device variants RTLS4060T CE article number 6GT2700 6DE03 RTLS4060T FCC article number 6GT2700 6DE13 RTLS4060T ISED article number 6GT2700 6DE33 Further documentation The system manual Commissioning SIMATIC RTLS provides information on other SIMATIC RTLS products that you can operate together with the devices in this product line in an Industrial Ethernet network You can find the system ma...

Page 6: ...er consultants at the following Internet address https new siemens com global en products services industry sitrain personal html Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants systems machines and networks In order to protect plants systems machines and networks against cyber threats it is necessary to im...

Page 7: ... to IEEE 802 15 4 2015 You will find details in the section Technical specifications Ensure that the radio frequencies are not used for other purposes and are not affected by other interfering signals This should be ensured within the operating range of the localization system Interference in the frequency band used can impair the system and in extreme cases lead to localization failure Physical a...

Page 8: ...Introduction SIMATIC RTLS4060T 8 Operating Instructions 01 2021 C79000 G8976 C550 03 ...

Page 9: ... sends position data to gateways which transmit the data to the Locating Manager server Area of application The transponder is suitable for installation in vehicles and other devices and is connected to the supply voltage there 2 2 Order data RTLS4060T Table 2 1 Order data RTLS4060T Article number SIMATIC RTLS4060T CE FCC ISED 6GT2700 6DE03 6GT2700 6DE13 6GT2700 6DE33 Table 2 2 Accessories order d...

Page 10: ...g in power connector digital inputs and outputs 8 pin plug in connector 3 m cable with socket article number 6GT2791 1AH30 Pin Description Color of the cable core 1 24 V DC Red 2 GND 0 V Black 3 Digital output Brown 4 Digital input 2 Orange 5 Digital input 1 Yellow 6 Not used Green 7 Not used Blue 8 Not used Violet ...

Page 11: ...istive capacitive and inductive loads The current is automatically limited to these functions Observe the value for the maximum current in section Technical specifications Page 15 A freewheeling diode DV is required for inductivities Digital input The device has 2 digital inputs Each has a range from 0 to 24 V with an impedance of 4 7 kOhm ...

Page 12: ...Device description SIMATIC RTLS4060T 12 Operating Instructions 01 2021 C79000 G8976 C550 03 2 4 Dimension drawing Figure 2 1 Dimension drawing SIMATIC RTLS4060T All dimensions specified in millimeters ...

Page 13: ...is to be performed by qualified and trained users according to the operating instructions In addition installation must take place in accordance with the respective instructions for the installation of electrical systems and utilities Note the specifications in the section Technical specifications Page 15 during installation and operation Make sure that the ambient temperature does not exceed 50 C...

Page 14: ......

Page 15: ... Transmit power 0 037 mW 41 3 dBm MHz Range Maximum 30 m Accuracy of the localization typical 0 2 m Antennas Built in UWB antenna PHASE radio frequencies communication and optional localization Wireless method IEEE 802 15 4 Transmission speed 1 Mbit s Operating frequency rated value 2405 MHz 2480 MHz Bandwidth 2 MHz data transmission on 802 15 4 channels configura ble Frequency range 2400 MHz 2482...

Page 16: ...sumption 7 W Permitted ambient conditions Ambient temperature During operation During transport During storage 15 C 50 C 15 C 50 C 15 C 50 C Design dimensions weights and connectors Dimensions L x W x H 66 x 151 x 43 mm Weight 180 g Degree of protection IP65 Method of securing 4 mounting holes for M5 screws Enclosure Plastic housing PC Color Light grey RAL 7035 Plug in connector 8 pin plug in conn...

Page 17: ...use of certain hazardous substances in electrical and electronic equipment official journal of the EU L174 1 July 2011 pages 88 110 Radio Equipment Directive 2014 53 EU RED Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market official journal of the EU L153 22 May 2014 pages ...

Page 18: ...ices Part 17 Specific conditions for broadband data transmission systems ETSI EN 301 489 33 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Part 33 Specific conditions for ultra wideband UWB devices EN 55011 Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measur...

Page 19: ... that may cause undesired operation Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against ha...

Page 20: ...fonctionnement UL WARNING Power supply The equipment is designed for operation with Safety Extra Low Voltage SELV by a Limited Power Source LPS This means that only SELV LPS complying with IEC60950 1 EN60950 1 VDE0805 1 must be connected to the power supply terminals The power supply unit for the equipment power supply must comply with NEC Class 2 as described by the National Electrical Code r ANS...

Page 21: ...Approvals SIMATIC RTLS4060T Operating Instructions 01 2021 C79000 G8976 C550 03 21 E1 The device meets the requirements of the ECE R10 directive Test number 10 R 058591 ...

Reviews: