Commissioning
3.4 Installing UPDD
Flat Panel
Operating Instructions (Compact), 09/2008, A5E02313712-01
19
3.4.3
Touch screen calibration
Procedure
1.
Select "Start > Programs > UPDD > Settings".
The "UPDD Console" dialog box opens.
Figure 3-6
Point calibration
2.
Select the screen (1) you wish to calibrate.
3.
Click on "Calibration" (2).
4.
Activate "25-point calibration" (3).
5.
Click on "Calibrate" (4).
The calibration mask is output on the selected display.
6.
Touch the blue arrow.
The input is confirmed by a tick, and the next arrow is displayed.
7.
Confirm all input prompts (arrows, or crosses in the center) until the complete screen has
been calibrated.
Note
If the touch screen does not react as expected when touched, repeat the calibration.
Only an active screen can be calibrated. An active screen is displayed in black, and a
deactivated screen in red.