Operating Manual - Elevator Door Operation AT18
11 Operating status display
The 7-segment display H5000 displays the following operating statuses:
Display
Meaning
0
Light barrier signal is in place (light barrier interrupted)
1
RAM, EEPROM or CPU error (system error)
EEPROM error
3
Error in the shut-off route
4
Increase of the hold open time at increased motor switch-on duration
5
Motor undefined*
6
Motor blocked in closing direction
7
Error pulse generator
8
Minimal editor is started (push service buttons
OPEN
and
CLOSE
at the same time)
9
Motor excess current
A
Minimal editor (force setting) active
b
Reserve
c
Blockage at opening
C
Minimal editor (profile setting) active
d
Door stays standing during initialisation drive (no
OPEN
and
CLOSE
signal)
E
Motor excess voltage
F
Motor excess voltage
h
Reserve
H
Parameter determination (teach-in drive)
n
Friction values of door too high
L
Current measurement error
o
Function OK
P
Parameter error (error in teach-in drive)
u
Door is closed
U
Maximum door weight exceeded
-
Controls wait for teach-in drive
* At the deployment of another motor type a renewed putting into operation according to this
operating manual must be done.