ST/BFOC connectors
The attachment to Industrial Ethernet uses ST/BFOC con‐
nector technology (Straight Tip/Bayonet Fiber Optic Connec‐
tor).
5.3
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
Spring-loaded terminals
connectable cable cross sec‐
tions for flexible cables ...
without wire end ferrule
0.2 - 1.5 mm
2
AWG: 24 - 14
with wire end ferrule with plastic
ferrule**
0.25 - 0.75 mm
2
AWG: 24 - 14
with TWIN wire end ferrule without
plastic ferrule**
0.25 - 1.5 mm
2
AWG: 24 - 18
Stripped length of the cable
10 mm
Wire end ferrule according to DIN 46228 without plastic ferrule**
10 mm
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp
cross sections.
Crimp shapes with wave-shaped profile are unsuitable.