Assembling
4.6 Wall mounting
SCALANCE X-300M PoE
26
Compact Operating Instructions, 05/2016, A5E02630810-09
Procedure
1.
On the rear of the housing, there are two recesses. Place these
on the top edge of the DIN rail.
2.
Then press the housing against the DIN rail until the spring
catch of the device locks onto the lower edge of the DIN rail.
3.
Secure the cable for the power supply and the data and any
other cables required (for example for the signaling contact)
according to the descriptions in the section "Connecting up".
Removing
1.
Remove all cables connected to the X-300.
2.
Use a screwdriver to lever down the spring catch of the device and pull the lower part of
the device away from the rail.
3.
Remove the device from the upper edge of the DIN rail.
4.6
Wall mounting
Wall mounting
1.
For wall mounting, use suitable mounting fittings for the wall
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws
3.5 mm diameter and 40 mm long).
2.
Connect the electrical cable connecting cables.