Deployment planning
4.3 Reset button - resetting the configuration to the factory settings
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
25
Insulation between the TP ports
Between the TP ports, an insulation voltage of 1.5 kV is adhered to (corresponds to
IEEE802.3, Section 33.4.1.1, Environment B).
See also
Technical specifications (Page 11)
4.3
Reset button - resetting the configuration to the factory settings
SCALANCE S switches have a reset button. The reset button is located on the rear of the
housing below the M32 plug immediately above the C-PLUG.
Image 4-1
Reset button and slot for the C-PLUG
Note
Make sure that only authorized personnel has access to the SCALANCE S device.
What does the reset button do?
Two functions can be triggered with the reset button:
●
Restart
The device is restarted. The loaded configuration is retained.
●
Reset to factory settings
The device is restarted and reset to the status set in the factory. A configuration loaded
on the SCALANCE S device or on an inserted C-PLUG is deleted.