![Siemens SCALANCE S623 Commissioning And Hardware Installation Manual Download Page 23](http://html.mh-extra.com/html/siemens/scalance-s623/scalance-s623_commissioning-and-hardware-installation-manual_377354023.webp)
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
23
Deployment planning
4
4.1
Unpacking and checking
Unpacking, checking
1.
Make sure that the package is complete.
2.
Check all the parts for transport damage.
WARNING
Do not use any parts that show evidence of damage.
4.2
Attachment to Ethernet
Possible attachments
Each SCALANCE S device has a certain number of ports to which the network nodes can be
connected. Depending on the interface, the network nodes are handled differently.
SCALANCE S device
Interface
Ports of the interface
Port type
SCALANCE S602 / S612
External
P1
Built-in RJ-45 jack (copper)
Internal
P2
Built-in RJ-45 jack (copper)
SCALANCE S623
External
P1
Built-in RJ-45 jack (copper)
Internal
P2
Built-in RJ-45 jack (copper)
DMZ
P3
Built-in RJ-45 jack (copper)
SCALANCE S627-2M
External
P1
Built-in RJ-45 jack (copper)
P4
Media module port (copper/FOC)
P5
Media module port (copper/FOC)
Internal
P2
Built-in RJ-45 jack (copper)
P6
Media module port (copper/FOC)
P7
Media module port (copper/FOC)
DMZ
P3
Built-in RJ-45 jack (copper)