RUGGEDCOM WIN7235
Installation Guide
Chapter 2
Installing the Base Station
Connecting to a RUGGEDCOM RP100 or RP110
17
CAUTION!
Crushing hazard – risk of damage to cables. Route all power supply cables so that people cannot walk
on them or place objects on or against them.
CONTENTS
•
Section 2.9.1, “Connecting to a RUGGEDCOM RP100 or RP110”
•
Section 2.9.2, “Connecting the Data Adapter”
•
Section 2.9.3, “Assembling the PoE Connector”
•
Section 2.9.4, “Installing the Hazardous Location Kit”
Section 2.9.1
Connecting to a RUGGEDCOM RP100 or RP110
The RUGGEDCOM RP100 and RP110 are optional power injectors for powering and providing data to the
RUGGEDCOM WIN7235. The RUGGEDCOM RP100 and RP110 meet a wider temperature and voltage range than
the standardRUGGEDCOM WIN1010.
When the base station is connected to a RUGGEDCOM RP100 or RP110, make sure there is a solid connection
between the lightning protector and the base station. The following illustration details a typical installation.
NOTE
A shielded cable must be used and connected to local ground at both the base station and lightning
protector.
NOTE
The lightning protector must meet the necessary requirements of IEC/UL/CSA 60950-1. The clamping
voltage must also be less than 60 V and the protector must not activate when the voltage is less than
56 V. For more information about these requirements, contact Siemens Customer Support.
IMPORTANT!
Install the lightning protector and the RUGGEDCOM RP100/RP110 as close as possible.