RUGGEDCOM WIN7023
Installation Guide
Chapter 2
Installing the Base Station
Installing Antennas
13
6
3
1
3
5
7
2
6
7
5
4
Figure 6: Base Station and Mounting Bracket Assembly
1.
Base Station
2.
Mounting Bracket
3.
Eye Bolt
4.
Top Plate
5.
Flat Washer
6.
Spring Washer
7.
Screw
4. Temporarily remove the eye bolts.
5. Secure the top plate to the mounting bracket using the screws, spring washers and flat washers removed
previously.
6. Install the eye bolts previously removed, securing the top plate to the base station.
7. Secure the bottom of the base station to the mounting bracket using the supplied flat washers, spring
washers, and 7.9 × 13 mm (5/16 × 1/2 in) screws.
8. Torque all screws to 8.9 N·m (6.6 lbf-ft).
Section 2.7
Installing Antennas
The base station supports external omni-directional and directional Global Positioning System (GPS) or Radio
Frequency (RF) antennas.
When selecting the ideal location for an antenna, consider the following recommendations:
• Mount the antenna at the highest possible point to improve reception.