![Siemens RUGGEDCOM RX5000 Installation Manual Download Page 31](http://html.mh-extra.com/html/siemens/ruggedcom-rx5000/ruggedcom-rx5000_installation-manual_381900031.webp)
RUGGEDCOM RX5000
Installation Guide
Chapter 3
Modules
Installing/Removing Line Modules
23
1
2
3
Figure 14: Removing a Module
1.
Chassis
2.
Module
3.
Screw
5. Install a new module or a blank module (to prevent the ingress of dust and dirt).
6. [Optional] If necessary, install the device in the rack.
7. Connect power to the device.
Installing a Line Module
To install a line module, do the following:
1. Make sure power to the device has been disconnected and wait approximately two minutes for any remaining
energy to dissipate.
2. [Optional] If the device is installed in a rack, remove it from the rack.
3. Remove the current module from the slot.
4. Insert the new module into the slot.