Chapter 2
Installing the Device
RUGGEDCOM RX5000
Installation Guide
16
Configuring the Device
11
5
6
9
Figure 10: Serial DB9 Console Port
Pin
Name
Description
1
DCD
Data Carrier Detect
2
RX
Receive Data
3
TX
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
8
CTS
Clear To Send
9
Reserved (Do Not Connect)
The management port is a 10/100Base-TX copper Ethernet port with an RJ45 connector. The following is the pin-
out for the management port:
1
8
Figure 11: RJ45 Management Port
Pin
Name
Description
1
TX+
Transmit Data+
2
TX-
Transmit Data-
3
RX+
Receive Data+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
RX-
Receive Data-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Communication Ports
Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM
ROX II console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM
RX5000 is
https://192.168.0.2
.
For more information about available ports, refer to
Chapter 3,
Modules
.
Section 2.10
Configuring the Device
Once the device is installed and connected to the network, it must be configured. All configuration management
is done via the RUGGEDCOM ROX II interface. For more information about configuring the device, refer to the
RUGGEDCOM ROX II User Guide
associated with the installed software release.