Modules
4.2 Installing/Removing Line Modules
Once a line module is removed, all the features associated with the module are hid-
den or disabled in RUGGEDCOM RX1512.
CAUTION
Electrical hazard – risk of power failure
Do not install more than one APE module. Installing more than two of this type of
module can lead to power fluctuations and irregular shut downs.
NOTICE
Only one WAN line module is supported per chassis.
CAUTION
Contamination hazard – risk of equipment damage
Prevent the ingress of water, dirts and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty and open ports are
protected with plugs or covers.
Removing a Module
To remove a line module, do the following:
1. [Optional] If the device is installed in a rack, remove it from the rack.
2. Loosen the screws that secure the module.
3. Pull the module from the chassis to disconnect it.
2
1
3
1
Module
2
Chassis
3
Screw
Figure 4.2
Removing a Module
4. Install a new module or a blank module (to prevent the ingress of dust and dirt).
30
RUGGEDCOM RX1512
Installation Manual, 07/2019, C79000-G8976-1057