Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severi-
ty Levels
1000 A/m for 1 s
IEC 61000-4-9
Pulse Magnetic Field
Enclosure Ports
300 A/m
4
IEC 61000-4-11
Voltage Dips & Interrupts
AC Power Ports
30% for 0.5 Cycles
60% for 5 Cycles
100% for 250 Cycles
Signal Ports
IEC 61000-4-16
Mains Frequency Voltage
DC Power Ports
30 V Continuous
300 V for 1s
4
IEC 61000-4-17
Ripple on DC
Power Supply
DC Power Ports
10%
3
IEC 61000-4-18
Damped Oscillatory Wave
Slow Damped
2.5 kV Common
100 kHz or 1 MHz
3
IEC 61000-4-29
Voltage Dips
and Interrupts
DC Power Ports
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal Ports
DC Power Ports
Dielectric Strength
AC Power Ports
2 kV
Signal Ports
IEC 60255-5
HV Impulse
DC Power Ports
5 kV
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RX1400 meets Class 1 requirements for copper ports, which allows
for temporary communication loss.
Test
Description
Test Levels
Signal Ports
HV Impulse
DC Power Ports
5 kV
Signal Ports
Dielectric Strength
DC Power Ports
2828 VDC or 2 kV
Signal Ports
DC Power Ports
Fast Transient (SWC)
Earth Ground Ports
± 4 kV @ 2.5 kHz, 5 kHz
Signal Ports
2.5 kV Common mode @1 MHz
Oscillatory (SWC)
DC Power Ports
2.5 kV Common Mode
1 kV Differential Mode @ 1 MHz
Radiated RFI
Enclosure ports
35 V/m
Enclosure Contact
± 8 kV
IEEE 1613
ESD
Enclosure Air
± 15 kV
RUGGEDCOM RX1400
Installation Manual, 09/2019, C79000-G8976-1103-13
55