3- Select spa configuration (if prompt on startup)
3
At first startup the keypad display
will show
Lx
or
LLx,
where « x »
representing the config. number. Some
spa packs come with a pre-selected
config. and you may skip this step if
your system automatically starts up
1
.
1
Note: To re-enter the low level
selection menu, hold the Pump 1
key for 30 seconds.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electrical config
and choose the
appropriate Low level.
2
Note: If the keypad does not have a
Program or Filter key, use the Light
key instead.
Use the
Up/Down
key to choose the
new low level configuration number.
Press the
Program
2
key to confirm the
selection.
2
1
1 phase connection
Phase jumpers
Position
PJ1
P7-P13
PJ2
P10-P74
2 phase connection
Phase jumpers
Position
PJ1
P7-P10
PJ2
P13-P74
3 phase connection (default)
Phase jumpers
Position
PJ1
P7-P10
PJ2
P11-P13
3 phase Delta connection
Phase jumpers
Position
PJ1
P7-P10
PJ2
P13-P74
2- Connect the main power
N
N
N
L3
L1
L1
L1
L2
L2
PJ1
PJ1
PJ1
PJ2
PJ2
PJ2
G
G
G
L3
L1
L2
PJ1
PJ2
G
Correct wiring of the electrical service
box, RCD, and pack terminal block is
essential. Power must be off during
this step.
input voltage: 230 V, 50 Hz (line-to-Neutral)
input voltage: 230 V, 50 Hz (line-to-line)
WARNING! All connections must be made by a qualified electrician in accordance with the national electrical code and any
state, provincial or local electrical code in effect at the time of the installation. This product must always be connected to circuit
protected by a residual-current device (RCD).
Determine jumper positions for number of phases
4- Select breaker current
98
Press and hold the
Program
key for
20 seconds until you access the
breaker setting menu.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electri-
cal config
and choose Input current.
The values displayed by the system
correspond to the maximum
amperage capacity of the RCD.
Use the
Up/Down
key to select the
desired value. Then press the
Program
key to confirm the selection.
Note
: If the keypad does not have the
Program
or
Filter
key, use the
Light
key instead.
Current setting for each phase setting
# of phases
Current setting range
1
10 to 48 A
2
10 to 20 A
3
10 to 16 A
Choose the number of phases
supplying your spa (1-3). Use the
Up/Down
key to select the desired
value. Then press the
Program
key to
confirm the selection.
Specify the current rating and the number of phases of the RCD used to ensure safe and efficient current mangement (and no RCD trippings).
2
3
4
1
1- Connect all outputs & keypads
For more information, see our
website: www.geckoalliance.com
For more information, see our
website: www.geckoalliance.com
Quick Start Card
in.ye-3-ce
™
& in.ye-5-ce
™
European version
Light outputs
(P34 always on, P35 relay controlled)
Main power
entry connection
Heater connections
Bonding lugs
A1
A2
A3
A4
Heater
A4 Optional
connector
AMP ports
(A0 to A4) for pumps
& accessories.
Functions varie
per configuration
(see next page).
Optional floating
connector
(Part #9920-401346)
A0
H
H
L
L
G
G
C
C
A4
A3
A2
A1
C1 - Main keypad connector
CO - Communication links (2 ports)
in.touch, in.stik, Aux keypad in.k112,
Swim Spa com. cable, etc.