3- Select spa configuration (if prompt on startup)

3

At first startup the keypad display 

will show 

Lx 

or

 LLx, 

where « x » 

representing the config. number. Some 

spa packs come with a pre-selected 

config. and you may skip this step if 

your system automatically starts up

1

.

Note: To re-enter the low level 

selection menu, hold the Pump 1 

key for 30 seconds.

 Note: 

For the 

Color keypad series

select 

Settings menu

, go into 

Electrical config

 and choose the 

appropriate Low level.

 

2

 

Note: If the keypad does not have a  

Program or Filter key, use the Light 

key  instead.

Use the 

Up/Down 

key to choose the 

new low level configuration number.

Press the 

Program

2

 

key to confirm the 

selection.

2

1

1 phase connection

Phase jumpers

Position

PJ1

P7-P13

PJ2

P10-P74

2 phase connection

Phase jumpers

Position

PJ1

P7-P10

PJ2

P13-P74

3 phase connection (default)

Phase jumpers

Position

PJ1

P7-P10

PJ2

P11-P13

3 phase Delta connection

Phase jumpers

Position

PJ1

P7-P10

PJ2

P13-P74

2- Connect the main power

N

N

N

L3

L1

L1

L1

L2

L2

PJ1

PJ1

PJ1

PJ2

PJ2

PJ2

G

G

G

L3

L1
L2

PJ1

PJ2

G

Correct wiring of the electrical service 

box, RCD, and pack terminal block is 

essential. Power must be off during 

this step.

input voltage: 230 V, 50 Hz (line-to-Neutral)

input voltage: 230 V, 50 Hz (line-to-line)

WARNING! All connections must be made by a qualified electrician in accordance with the national electrical code and any 

state, provincial or local electrical code in effect at the time of the installation. This product must always be connected to circuit 

protected by a residual-current device (RCD).

Determine jumper positions for number of phases

4- Select breaker current

98

Press and hold the 

Program 

key for 

20 seconds until you access the 

breaker setting menu.

Note:

 For the 

Color keypad series

select 

Settings menu

, go into 

Electri-

cal config

 and choose Input current.

The values displayed by the system 

correspond to the maximum 

amperage capacity of the RCD.

Use the 

Up/Down

 key to select the 

desired value. Then press the 

Program 

key to confirm the selection.

Note

: If the keypad does not have the 

Program

 or 

Filter

 key, use the 

Light

 

key instead.

Current setting for each phase setting

# of phases

Current setting range

1

10 to 48  A

2

10 to 20 A

3

10 to 16 A

Choose the number of phases 

supplying your spa (1-3). Use the 

Up/Down

 key to select the desired 

value. Then press the 

Program

 key to 

confirm the selection.

Specify the current rating and the number of phases of the RCD used to ensure safe and efficient current mangement (and no RCD trippings). 

2

3

4

1

1- Connect all outputs & keypads

For more information, see our 

website: www.geckoalliance.com

For more information, see our 

website: www.geckoalliance.com

Quick Start Card

in.ye-3-ce

 & in.ye-5-ce

 European version

Light outputs

(P34 always on, P35 relay controlled)

Main power

entry connection

Heater connections

Bonding lugs

A1

A2

A3

A4

Heater 

A4 Optional 

connector

AMP ports 

(A0 to A4) for pumps 

& accessories. 

Functions varie 

per configuration 

(see next page).

Optional floating 

connector 

(Part #9920-401346)

A0

H

H

L

L

G

G

C

C

A4

A3

A2

A1

C1 - Main keypad connector

CO - Communication links (2 ports)

in.touch, in.stik, Aux keypad in.k112, 

Swim Spa com. cable, etc.