Technical Specifications
5.6 Operating Environment
Tx (dBm)
Mode
Connector
Type
Cable
Type
(µm)
Tx λ
(nm)
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
Power
Budget
(dB)
MM
LC
50/125
850
-9
-2.5
-20
0
0.5
11
MM
LC
62.5/125
850
-9
-2.5
-20
0
0.5
11
SM
SC
9/125
1310
-10
-3
-20
-3
10
10
SM
LC
9/125
1310
-9.5
-3
-21
-3
10
11.5
SM
SC
9/125
1310
-5
0
-20
-3
25
15
SM
LC
9/125
1310
-7
-3
-24
-3
25
17
All cabling is duplex type unless specified otherwise.
Typical.
All optical power numbers are listed as dBm averages.
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of
patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
GBIC Gigabit (1 Gbps) Transceiver Specifications
Note
GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless
specified otherwise.
Tx (dBm)
Mode
Connector
Type
Cable
Type
(µm)
Tx λ
(nm)
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
Power
Budget
(dB)
SM
SC
9/125
1310
-9.5
-3
-21
-3
10
11.5
SM
SC
9/125
1310
-7
-3
-24
-3
25
17
SM
SC
9/125
1550
0
5
-23
-3
70
23
All cabling is duplex type unless specified otherwise.
Typical.
All optical power numbers are listed as dBm averages.
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of
patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
Operating temperature range of -25 to 85 °C (-13 to 185 °F).
5.6
Operating Environment
The RUGGEDCOM RSG2300F is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
-40 to 85°C (-40 to 185 °F)
Ambient Storage
Temperature
-40 to 85°C (-40 to 185 °F)
Ambient Relative
Humidity
5% to 95%
Maximum Altitude
2000 m (6562 ft)
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Non-condensing
34
RUGGEDCOM RSG2300F
Installation Manual, 04/2021, C79000-G8976-1347-09